5-30
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 5 Maintenance and Alignment
!
WARNING:
REFLECTED POWER CALIBRATION MUST BE COMPLETED FIRST TO PROVIDE
VSWR PROTECTION DURING THE FORWARD POWER CALIBRATION PROCE-
DURE. THIS REQUIRES THE USE OF AN EXTERNAL WATT METER CAPABLE OF
READING 300 WATTS.
5.16 Removing/Replacing Firmware ICs
Each of the controller boards, with the exception of the Life Support Board, have 2
Firmware ICs which contain the software for the microcontrollers. It is possible that
these may need to be replaced as part of a firmware upgrade, or they may need to be
transferred from a defective controller board to a new one. Each of these IC’s has a
printed label on top which gives:
a.
The part number of the software.
b.
The revision number for the software.
c.
A U## component designator to locate the correct socket on the board. The fol-
lowing is a list of the component designators for each of the Firmware IC’s:
1.
Master Controller - U18 and U28
2.
PA Controllers - U23 and U30
3.
PS Controller - U5 and U8
!
WARNING:
BE SURE TO USE AN ANTI-STATIC WRIST STRAP WHEN HANDLING PC BOARDS
OR IC’S TO PREVENT DAMAGE TO THE COMPONENTS.
5.16.1 Firmware IC removal:
STEP 1
Shut off the Low Voltage breaker in the back of the transmitter. Pull out
the controller and remove the pc board hold-down bracket.
STEP 2
It will be necessary to remove the appropriate PC board and place it on an
anti-static work surface (a large anti-static bag works well if an anti-static
mat is not available). PA and PS controllers have cables attached at the rear
of the card whose position should be noted before removal.
STEP 3
Note that the PA and PS Controllers have an ID setting which means
they must be placed back in the same slot from which they were
removed.
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...