NetWave DirectView Broadcast Console Operations & Technical Manual
Revision A
5 – NetWave Servicing
Harris Broadcast
5-10
PR&E
The Active Channel display number blinks and all A and B labels on the eight channels on that DSP
card blink to indicate the mode is active. All eight channels are assigned to all Program buses and the
active channel is turned on to a nominal output level (faders are bypassed in this mode). Press Option
+ Channel Down to go to Parameter Set Mode, then press Store to return the card to Sleep Mode.
●
DSP & I/O User Interface Test – This mode is used to verify that the LEDs, displays and switches on
the DSP card are working properly. It is entered by pressing Option + Fader Start while in the Data
Path Test Mode.
All of the setup LEDs and displays on the DSP card are turned on so their operation can be verified. Press
each switch to verify the LEDs and displays turn off while the switch is held. To exit this mode, press
Option + Fader Start to exit to Parameter Set Mode, then press Store to return the card to Sleep
Mode.
●
Factory Reset – This mode resets the channel parameters and channel strip controls to their factory
defaults. To do this, press Option + Store in any mode. The stored parameters for all channel A and B
sources are erased and replaced with the factory default settings (Analog; Stereo; Line; trims set to 0;
all other buttons off; all network sources Analog). All channel strip controls are unassigned and set to
the A source.