Appendix 6. Alarm List
337
Appendi
x
252
When the 5th axis moves along the + direction, the tool enters into the
inhibited area defined by a stroke limit 1.
253
When the 5th axis moves along the - direction, the tool enters into the
inhibited area defined by a stroke limit 1.
400
X, Y, Z axes overload
401
The speed control ready signal (VRDY) for X, Y, Z axes is cut OFF.
402
Auxiliary axis overload.
403
Speed control ready signal (VRDY) for the auxiliary axis is cut OFF.
404
Although the position control ready signal (PRDY) is OFF, the speed control
ready signal (VRDY) is not cut OFF; after power-on, the ready signal (PRDY)
is not ON, but the speed control ready signal (VRDY) is ON.
405
The reference point return cannot be performed due to the abnormalities
within the NC or servo system.
407
The speed control ready signal (VRDY) of the 5th axis is OFF.
410
The position deviation value on X axis stop state exceeds the setting value.
411
The position deviation value on X axis moving state exceeds the setting
value.
412
The deviation value on X axis is excessive (more than 500 VELO)
413
The position deviation value of X axis exceeds ±32767, or the speed
command value of DA converter is beyond the range
+8191
~
-8192.
This
alarm occurs usually because of setting error.
414
The position detection device of rotating transformer and inductosyn for X
axis is in abnormal state.
415
The specified feedrate of X axis exceeds 511875 detection unit/s. This alarm
occurs because of CMR setting error.
416
The position device of pulse coder for the X axis is in abnormal state.
(disconnection alarm)
417
The servo position loop LSI of the X axis is defective.
420
The position deviation value in Y axis stop state exceeds the setting value.
421
The position deviation value in Y axis moving state exceeds the setting value.
422
The deviation value of Y axis is excessive. (more than 500 VELO)
423
The position deviation value of Y axis exceeds ±32767, or the speed
command value of DA converter is beyond the range +8191
~
-8192. This
alarm occurs usually because of setting error.
424
The position detection device of rotating transformer and inductosyn for Y
axis is in abnormal state.
425
The specified feedrate of Y axis exceeds 511875 detection unit/s. This alarm
occurs because of CMR setting error.
426
The position device of pulse coder for the Y axis is in abnormal state.
(disconnection alarm)
427
The servo position loop LSI of the X axis is defective.
430
The position deviation value in Z axis stop state exceeds the setting value.
Summary of Contents for GSK983Ma
Page 124: ......
Page 143: ......
Page 185: ......
Page 209: ...Chapter Four Operation 197 Part 2 Operation ...
Page 239: ...Chapter Four Operation 227 Part 2 Operation ...
Page 242: ......
Page 279: ......
Page 296: ...GSK983Ma Milling Machine Center CNC System User Manual 284 Part 2 Operation ...
Page 371: ...Appendix 11 USB Interface Parameter Transfer Operation ...