I DVICE select the input device storing data to the memory. When the set input device is
(
INPUT
DEVICE
)
2=1, this setting is valid.
O DVICE select the output device that is used for data outputting or set by parameter.
Setting
Input / output device
0
USB interface
2
RS232 interface is used for input and output. Set baud rate and other
parameter to 311.
Setting (valid when the program lock is ON, invalid when it is locked,whose state can be
switched by parameter 11 BIT5 DECI)
(
a
)
Select MDI mode.
(
b
)
Press the cursor key to move the cursor to the item to be altered. The cursor cannot be
move with the address key N.
(
c
)
During operation, press P Numerical key and INPUTkey in succession.
4.4.8.2 Display and Setting of User Macro Program Variables
It is possible to display all common variable values and local variable values of currently called
user macro program body on LCD.
When a variable value is <null>, the display will be blank. When an absolute value is over
99999999, it displays “OVER FLOW”. When an absolute value is not zero, but less than 0.0000001, it
displays “UNDR FLOW”.
(
1
)
Select MACRO of the page SET.
Press SETTING key to enter SETTING DISPLAY page. Press it again to enter MACRO page.
(
2
)
Because the display concludes six pages, it is necessary to press PAGE key to display the
required page.
Page 1——Local variables #1-#20 of currently called nest.
Page 2——Local variables #21-#33 of currently called nest.
Page 3——Common variable #100-#119
。
Page 4——Common variable #120-#139
。
Page 5——Common variable #140-#149
。
Page 6——Common variable #500-#511
。
(
3
)
The cursor can be moved to the position to be displayed
Method 1: Press the cursor and move the cursor in succession. It switches to the next page once
Summary of Contents for GSK983Ma
Page 124: ......
Page 143: ......
Page 185: ......
Page 209: ...Chapter Four Operation 197 Part 2 Operation ...
Page 239: ...Chapter Four Operation 227 Part 2 Operation ...
Page 242: ......
Page 279: ......
Page 296: ...GSK983Ma Milling Machine Center CNC System User Manual 284 Part 2 Operation ...
Page 371: ...Appendix 11 USB Interface Parameter Transfer Operation ...