GSK983Ma Milling Machine Center CNC System User Manual
190
Part 1 Programming
the edition of common programs. As described in Section 11.1, modified program shall be executed;
otherwise it cannot be saved in the tool life data area.
3.11.4.2 The display of tool life data during the execution of machine program
Pressing the key of the DIAGNOSIS twice in any mode displays the first page of tool life data in
the following format on the screen of LCD.
Group No.
Life
Currently used number
TOOL L I F F DA TA 01
:
0 0 0 0 1 N 0 0 1 2
SELECTED GRP 0 0 1
GRP 0 0 1
:
LIFE 9800 COUNT 6501
Life counter
*0 0 3 4 * 0 0 7 8 * 0 0 1 2 * 0 0 5 6
*0 0 9 0 @0 0 7 6 0 0 3 2 0 0 9 8
Tool number in the group 1
0 0 5 4 0 0 1 0 0 0 9 9 0 0 8 7
*
:
Tool life end
0 0 7 7 0 0 6 6 0 0 5 5 0 0 2 4
(
@
):
Tool is being used.
GRP 0 0 2
:
LIFE 0 5 0 0 COUNT 0112
#:
Tool has been skipped
*0 0 1 1 *0 0 2 2 *0 2 0 1 *0 1 4 4
*0 1 5 5 *0 0 6 6 *0 1 7 6 *0 1 8 8 Tool number in the goup 2.
#0 0 1 9 0 2 3 4 0 0 0 7 0 1 1 2
0 1 5 6 0 0 9 0 0 0 1 6 0 2 3 2
GRP T O BE CHANGED
:
0 0 3 0 0 6 0 1 2 0 1 3 0 1 4
T
ool group number to be changed
N LSK INC
Two groups of data are displayed on each page. Pressing the page turning button
↓
displays all
data groups in sequence. Tool change signal may be given to up to 5 groups, which are displayed at
the bottom of each page. For 6 or more groups, an arrow will be indicated in the diagram.
To review the data, select address N, enter the group number and press the INPUT button, or
pressure press the CURSOR
↓
button to move the cursor to the GRP of the next group and to display
its data.
3.11.4.3 Presetting of the Tool Life Counter
The MDI mode should be selected for modifying the life counter.
(I) P
□□□□
and press the INPUT button.
In this case, the group counter that is identified by the cursor is preset
□□□□
while other data in
the group remains unchanged.
(II) Type in P
-
9999 and press the INPUT button
All the executed data in the group identified by the cursor including * are cleared. It functions as
the reset of the tools in the group (see Section 3.11.3.2).
3.11.5 Other Cautions
Part program storage and edition area will reduce the storage area in the last part for the purpose
of tool life data area. When data is saved in the part program and edition area in EDIT mode as
described in Section 11.1, more area will be occupied.
Summary of Contents for GSK983Ma
Page 124: ......
Page 143: ......
Page 185: ......
Page 209: ...Chapter Four Operation 197 Part 2 Operation ...
Page 239: ...Chapter Four Operation 227 Part 2 Operation ...
Page 242: ......
Page 279: ......
Page 296: ...GSK983Ma Milling Machine Center CNC System User Manual 284 Part 2 Operation ...
Page 371: ...Appendix 11 USB Interface Parameter Transfer Operation ...