(b) If the interference occurs after the (a) is modified, the tool is then stopped due to an alarm.
If the interference occurs at the last vector while the (a) is checking or only one pair of vectors at
the beginning of the checking and the vectors interfere, the alarm No.41 is generated and the tool is
stopped immediately after execution of the preceding block.
The interference is still generated between V
1
and V
6
, even though the vectors V
2
and V
5
are
ignored due to the interference. In this case, the alarm occurs and the operation is then stopped.
3) The check is still performed even if the actual interference does not occur, refer to the
following examples:
(a) Depression which is smaller than the cutter compensation value