GSK983Ma Milling Machine Center CNC System User Manual
310
Appendi
x
0 9 8
0 9 9
4 2 9
LINTX, LINTY, LINTZ, LINT4, LINT5 respectively set the time constant of linear acceleration and
deceleration for X, Y, Z, 4th, 5th axes (for rapid traverse).
Setting value: 8
~
4000 unit: ms
1 0 0
1 0 1
1 0 2
1 0 3
4 3 0
EXPTZ, EXPTY, EXPTZ, EXPT4, EXPT5 respectively set the exponential
acceleration/deceleration time constant when manual feed for X, Y, Z, 4th, 5th axes.
Setting value: 8
~
4000 unit: ms
1 0 5
FEEDT: the exponential acceleration/deceleration time constant in cutting feed.
Setting value: 8
~
4000 unit: ms
1 0 6
A type Parameter No.318
(
ADNW = 0
)
can be applied to all axes. The permitted tangential
speed cannot be exceeded, otherwise the feedrate are controlled within the range.
Setting value: 6
~
60000 unit: mm/min
,
deg/min (metric output)
6
~
2400 unit: 0.1inch/min
,
0.1deg/min or 1deg/min
(
inch output
)
Note: in inch output mode, whether the unit of auxiliary axis is 0.1deg/min or 1deg/min is determined
by parameter ROT10 (No. 306).
B type parameter No.318 can be applied to X, Y, Z axes. The tangential speed during
circular interpolation (axes feedrate during linear interpolation) cannot exceed the
permitted range; otherwise, the feedrate will be controlled within the range.
Setting value: 6
~
15000 unit:mm/min
(
metric output
)
6
~
6000 unit: 0.1inch/min
(
inch output
)
(Refer to parameter No. 366 for auxiliary axis)
1 0 7
EXDEC sets the external deceleration (for all axes); relevant parameter No. 021
LINTZ
LINT4
LINT5
EXPTX
EXPTY
EXPTZ
EXPT4
EXPT5
FEEDT
FEDMX
EXDEC
Summary of Contents for GSK983Ma
Page 124: ......
Page 143: ......
Page 185: ......
Page 209: ...Chapter Four Operation 197 Part 2 Operation ...
Page 239: ...Chapter Four Operation 227 Part 2 Operation ...
Page 242: ......
Page 279: ......
Page 296: ...GSK983Ma Milling Machine Center CNC System User Manual 284 Part 2 Operation ...
Page 371: ...Appendix 11 USB Interface Parameter Transfer Operation ...