GSK983Ma Milling Machine Center CNC System User Manual
334
Appendi
x
not found.
079
The program after communication is different with the original one. (program
comparison)
084
Programs cannot be edited because the commands for start point, end point
or movement end point are incorrect in the extended edit function.
085
The number of bits of input data or setting of baud rate is incorrect when data
are entered into the memory by using RS232, DNC interface.
086
Abnormal transmission or I/O device error occurs when data are entered into
the memory by using RS232 interface.
087
Data with over 10 characters is input after the DC3 (stop code) is sent when
data are entered into the memory by using RS232, DNC interface.
090
During the reference return in grid mode, the one-rotation signal (standard
origin signal when linear scale) from the pulse coder is not input. Reference
point return cannot be performed correctly.
091
During the reference return in grid mode, the one-rotation signal (standard
origin signal when linear scale) is unsynchronized with the standard counter
because of slow speed. Reference point return cannot be performed
correctly.
092
Reference point return cannot be performed on the axis specified by G27.
094
P type cannot be specified when the program is restarted. (Because after the
program is interrupted, the coordinate system setting operation or zero
clearing is performed.)
095
P type cannot be specified when the program is restarted. (After the program
is interrupted, the external workpiece offset amount is changed).
096
P type cannot be specified when the program is restarted. (after the program
is interrupted, the workpiece offset amount is changed)
097
P type cannot be specified when the program is restarted. (After power-on,
emergency stop or stored limit alarm are cleared, no automatic operation is
performed.)
098
A command of the program restart is specified without the reference position
return operation after power-on or emergency stop or stored limit alarm is
cleared, and G28 is found during the search.
099
After completion of search in program restart, a move command is given in
MDI mode.
100
The parameter writing is ON. Set it to OFF, then reset the system.
101
The power is turned OFF when rewriting the memory by program storing and
edit operation. If this alarm occurs, press
and
at the same
time, and the stored program will be deleted.
102
The power is OFF when the data of tool life management is written.
110
The absolute value of fixed decimal point display data exceeds the allowable
range.
111
The data displayed with float decimal point exceeds the ceiling level.
112
The division by zero is specified.
113
A function which cannot be used in custom macro is commanded.
114
There is an error in other formats than (FORMAT).
Summary of Contents for GSK983Ma
Page 124: ......
Page 143: ......
Page 185: ......
Page 209: ...Chapter Four Operation 197 Part 2 Operation ...
Page 239: ...Chapter Four Operation 227 Part 2 Operation ...
Page 242: ......
Page 279: ......
Page 296: ...GSK983Ma Milling Machine Center CNC System User Manual 284 Part 2 Operation ...
Page 371: ...Appendix 11 USB Interface Parameter Transfer Operation ...