GSK983Ma Milling Machine Center CNC System User Manual
322
Appendi
x
0 1 1 4
1 0 0 5
3 1 6
CDSCG 1: the DSCG feedback (for rotating transformer and inductosyn) frequency
detection is not performed.
0: the DSCG feedback (for rotating transformer and inductosyn) frequency
detection is performed.
(This parameter is set to 0 after initialization)
ACMR 1: CMP setting can be performed.
(
caution
)
0: CMP setting cannot be performed.
DSCGX
、
Y
、
Z
、
4
、
5
DSCGX, DSCGY, DSCGZ, DSCG4, DSCG5 respectively set the types of position detection
systems for X, Y, Z, 4th, 5th axes.
1: the position detection system is rotating transformer or inductosyn
0: the position detection system is pulse coder.
Note: Pulse coder and rotating transformer/inductosyn cannot be used at the same time in X, Y, Z, 4th, 5th
axes.
3 1 8
PRG9 1: The programDS6 rcy