![Gestetner G060 Service Manual Download Page 138](http://html1.mh-extra.com/html/gestetner/g060/g060_service-manual_2217717138.webp)
SC TABLE
G060 4-24
SM
SC No.
Item
Definition
Possible Cause
Related
SCs
Troubleshooting Procedure
Type
SC 621
Finisher/mailbox
communication
error
SC 622
Bank
communication
error
•
Cable problems
•
BCU problems
•
PSU problems in the
machine
•
Main board problems
in the peripherals
1. Turn the main switch off and on.
2. Check if the cables of peripherals are
properly connected.
3. Replace the PSU if no power is
supplied to peripherals.
4. Replace the BCU or main board of
peripherals.
SC 623
Duplex unit
communication
error
While the BCU communicates
with an optional unit, an SC
code is displayed if one of
following conditions occurs.
1. The BCU receives a signal
which is generated by the
peripherals only just after
the main switch is turned
on.
2. When the BCU does not
receive an OK signal from a
peripheral 100ms after
sending a command to it.
The BCU resends the
command. The BCU does
not receive an OK signal
after sending the command
3 times.
•
Cable problems
•
BCU problems
•
PSU problems in the
machine
•
Duplex control board
problem
1. Turn the main switch off and on.
2. Check if the cable of the duplex
inverter unit is properly connected.
3. Replace the PSU if no power is
supplied to the peripherals.
4. Replace the duplex control board in
the inverter unit.
SC 640
BCU -
Controller
communication
error (check
sum error)
The check sum of the interface
between the BCU and
controller is not the same.
•
Defective controller
•
Defective PCU
1. Turn the main switch off and on.
2. Replace the controller.
3. Replace the BCU.
CTL
SC 641
BCU –
Controller
communication
error (no
response)
The controller does not receive
any response from the BCU
three consecutive times when
sending a signal every 100ms.
•
Loose connection
•
Defective controller
•
Defective BCU
1. Turn the main switch off and on.
2. Check the connection between the
BCU and controller.
3. Replace the controller.
4. Replace the BCU.
CTL
SC 660
BCU NVRAM
read/write
diagnostics
error
A read/write diagnostics error
is detected when the main SW
is turned ON.
Note:
This only occurs with the
8kB NVRAM.
•
Defective 8kB
NVRAM (BCU)
1. Turn the main switch OFF/ON.
2. Replace the NVRAM.
⇒
Rev. 09/2003
Summary of Contents for G060
Page 1: ...G060 G570 G082 SERVICE MANUAL 001159MIU RICOH GROUP COMPANIES...
Page 2: ......
Page 3: ...G060 G570 G082 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 4: ......
Page 5: ...G570 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 6: ......
Page 7: ...G570 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 8: ......
Page 9: ...G060 G570 G082 SERVICE MANUAL 001159MIU...
Page 10: ......
Page 12: ......
Page 14: ......
Page 16: ......
Page 38: ......
Page 42: ......
Page 44: ......
Page 45: ...INSTALLATION...
Page 46: ......
Page 58: ......
Page 59: ...PREVENTIVE MAINTENANCE...
Page 60: ......
Page 64: ......
Page 65: ...REPLACEMENT AND ADJUSTMENT...
Page 66: ......
Page 112: ......
Page 113: ...TROUBLESHOOTING...
Page 114: ......
Page 167: ...SERVICE TABLES...
Page 168: ......
Page 229: ...DETAILED DESCRIPTIONS...
Page 230: ......
Page 307: ...DUPLEX UNIT G571...
Page 308: ......
Page 321: ...ONE TRAY PAPER FEED UNIT G567...
Page 322: ......
Page 331: ...TWO TRAY PAPER FEED UNIT G568...
Page 332: ......
Page 341: ...LARGE CAPACITY TRAY G569...
Page 342: ......
Page 360: ......
Page 361: ...TWO TRAY FINISHER G565...
Page 362: ......
Page 393: ...FOUR BIN MAILBOX G566...
Page 394: ......
Page 402: ......
Page 403: ...SPECIFICATIONS...
Page 404: ......
Page 415: ...G570 SERVICE MANUAL...
Page 416: ......
Page 417: ...COPIER FEATURE EXPANDER G570...
Page 418: ......
Page 482: ......
Page 654: ......
Page 668: ......
Page 669: ...ARDF G564...
Page 670: ......
Page 694: ......
Page 695: ...FAX UNIT G307...
Page 696: ......
Page 812: ......
Page 835: ...G082...
Page 836: ......
Page 846: ......
Page 848: ......
Page 882: ......
Page 883: ...TECHNICAL SERVICE BULLETINS...
Page 925: ...FIRMWARE HISTORY...
Page 926: ......
Page 1077: ...FIRMWARE HISTORY...