![Gestetner G060 Service Manual Download Page 130](http://html1.mh-extra.com/html/gestetner/g060/g060_service-manual_2217717130.webp)
SC TABLE
G060
4-16
SM
SC No.
Item
Definition
Possible Cause
Related
SCs
Troubleshooting Procedure
Type
SC 460-
001
Thermistor 1
error (open
circuit)
When the temperature
detected by thermistor 1,
which is at the left (fusing unit)
side of the laser optics unit, is
less than -30°C for 10 seconds
consecutively, the BCU
determines that the circuit is
opened and displays this SC
code..
•
Thermistor 1
defective
•
Cable connection
error
•
BCU defect
1. Turn the main switch off and on.
2. Check the cable connections.
3. Replace the thermistor.
4. Replace the BCU.
SC 460-
002
Thermistor 1
error (short
circuit)
When the temperature
detected by the thermistor 1,
which is at the left (fusing unit)
side of the laser optics unit, is
higher than 70°C for 10
seconds consecutively, the
BCU determines that the
circuit is shorted and displays
this SC code
•
Thermistor 1
defective
•
Cable connection
error
•
BCU defect
1. Turn the main switch off and on.
2. Check the cable connections.
3. Replace the thermistor.
4. Replace the BCU.
SC 461-
001
Thermistor 2
error (open
circuit)
When the temperature
detected by the thermistor 2,
which is at the right (paper
feed section) side of the laser
optics unit, is less than -30°C
for 10 seconds consecutively,
the BCU determines that the
circuit is opened and displays
this SC code.
•
Thermistor 2
defective
•
Cable connection
error
•
BCU defect
1. Turn the main switch off and on.
2. Check the cable connections.
3. Replace the thermistor.
4. Replace the BCU.
Summary of Contents for G060
Page 1: ...G060 G570 G082 SERVICE MANUAL 001159MIU RICOH GROUP COMPANIES...
Page 2: ......
Page 3: ...G060 G570 G082 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 4: ......
Page 5: ...G570 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 6: ......
Page 7: ...G570 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 8: ......
Page 9: ...G060 G570 G082 SERVICE MANUAL 001159MIU...
Page 10: ......
Page 12: ......
Page 14: ......
Page 16: ......
Page 38: ......
Page 42: ......
Page 44: ......
Page 45: ...INSTALLATION...
Page 46: ......
Page 58: ......
Page 59: ...PREVENTIVE MAINTENANCE...
Page 60: ......
Page 64: ......
Page 65: ...REPLACEMENT AND ADJUSTMENT...
Page 66: ......
Page 112: ......
Page 113: ...TROUBLESHOOTING...
Page 114: ......
Page 167: ...SERVICE TABLES...
Page 168: ......
Page 229: ...DETAILED DESCRIPTIONS...
Page 230: ......
Page 307: ...DUPLEX UNIT G571...
Page 308: ......
Page 321: ...ONE TRAY PAPER FEED UNIT G567...
Page 322: ......
Page 331: ...TWO TRAY PAPER FEED UNIT G568...
Page 332: ......
Page 341: ...LARGE CAPACITY TRAY G569...
Page 342: ......
Page 360: ......
Page 361: ...TWO TRAY FINISHER G565...
Page 362: ......
Page 393: ...FOUR BIN MAILBOX G566...
Page 394: ......
Page 402: ......
Page 403: ...SPECIFICATIONS...
Page 404: ......
Page 415: ...G570 SERVICE MANUAL...
Page 416: ......
Page 417: ...COPIER FEATURE EXPANDER G570...
Page 418: ......
Page 482: ......
Page 654: ......
Page 668: ......
Page 669: ...ARDF G564...
Page 670: ......
Page 694: ......
Page 695: ...FAX UNIT G307...
Page 696: ......
Page 812: ......
Page 835: ...G082...
Page 836: ......
Page 846: ......
Page 848: ......
Page 882: ......
Page 883: ...TECHNICAL SERVICE BULLETINS...
Page 925: ...FIRMWARE HISTORY...
Page 926: ......
Page 1077: ...FIRMWARE HISTORY...