![Gestetner G060 Service Manual Download Page 131](http://html1.mh-extra.com/html/gestetner/g060/g060_service-manual_2217717131.webp)
SC TABLE
SM
4-17
G060
SC No.
Item
Definition
Possible Cause
Related
SCs
Troubleshooting Procedure
Type
SC 461-
002
Thermistor 2
error (short
circuit)
When the temperature
detected by the thermistor 2,
which is at the right (paper
feed section) side of the laser
optics unit, is higher than 70°C
for 10 seconds consecutively,
the BCU determines that the
circuit is shorted and displays
this SC code
•
Thermistor 2
defective
•
Cable connection
error
•
BCU defect
1. Turn the main switch off and on.
2. Check the cable connections.
3. Replace the thermistor.
4. Replace the BCU.
SC 471
Transfer belt
H.P. error
The transfer belt HP sensor
signal does not change from
Low to High (home position) or
vice versa 1 second after the
transfer belt contact motor
turns on.
•
Transfer belt unit not
set properly
•
Defective transfer belt
H.P. sensor and/or
transfer belt set
sensor
•
Defective transfer belt
contact motor
•
Transfer belt unit
problem
1. Turn the main switch off and on.
2. Reset the transfer belt unit.
3. Clean or replace the transfer belt H.P.
sensor and/or transfer belt set sensor.
4. Replace the transfer belt contact
motor.
5. Check the contact and release
mechanism of the transfer belt unit.
SC 490
Transfer bias /
paper
attraction roller
bias leak error
The high voltage supply board
(T/PA/CL) monitors the circuit
and detects current leaks. If
this happens, the high voltage
supply board sends a SC
signal (High to Low at CN213-
8) to the BCU.
The BCU monitors this signal
every 2 ms and generates this
SC code when the error
condition occurs 250
consecutive times.
•
Defective high
voltage supply board
(T/PA/CL)
•
Damaged transfer
belt
•
Transfer unit
•
Damaged high
voltage supply cables
•
Damaged cables
between the BCU and
high voltage supply
board
•
Defective BCU
1. Turn the main switch off and on.
2. Check the transfer unit and replace
the belt and/or the transfer unit if any
damage is found.
3. Replace the high voltage supply
board (T/PA/CL).
4. Check and/or replace the high voltage
supply cables.
5. Check and/or replace the dc cables
between the BCT and high voltage
supply board.
6. Replace the BCU.
Summary of Contents for G060
Page 1: ...G060 G570 G082 SERVICE MANUAL 001159MIU RICOH GROUP COMPANIES...
Page 2: ......
Page 3: ...G060 G570 G082 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 4: ......
Page 5: ...G570 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 6: ......
Page 7: ...G570 SERVICE MANUAL RICOH GROUP COMPANIES...
Page 8: ......
Page 9: ...G060 G570 G082 SERVICE MANUAL 001159MIU...
Page 10: ......
Page 12: ......
Page 14: ......
Page 16: ......
Page 38: ......
Page 42: ......
Page 44: ......
Page 45: ...INSTALLATION...
Page 46: ......
Page 58: ......
Page 59: ...PREVENTIVE MAINTENANCE...
Page 60: ......
Page 64: ......
Page 65: ...REPLACEMENT AND ADJUSTMENT...
Page 66: ......
Page 112: ......
Page 113: ...TROUBLESHOOTING...
Page 114: ......
Page 167: ...SERVICE TABLES...
Page 168: ......
Page 229: ...DETAILED DESCRIPTIONS...
Page 230: ......
Page 307: ...DUPLEX UNIT G571...
Page 308: ......
Page 321: ...ONE TRAY PAPER FEED UNIT G567...
Page 322: ......
Page 331: ...TWO TRAY PAPER FEED UNIT G568...
Page 332: ......
Page 341: ...LARGE CAPACITY TRAY G569...
Page 342: ......
Page 360: ......
Page 361: ...TWO TRAY FINISHER G565...
Page 362: ......
Page 393: ...FOUR BIN MAILBOX G566...
Page 394: ......
Page 402: ......
Page 403: ...SPECIFICATIONS...
Page 404: ......
Page 415: ...G570 SERVICE MANUAL...
Page 416: ......
Page 417: ...COPIER FEATURE EXPANDER G570...
Page 418: ......
Page 482: ......
Page 654: ......
Page 668: ......
Page 669: ...ARDF G564...
Page 670: ......
Page 694: ......
Page 695: ...FAX UNIT G307...
Page 696: ......
Page 812: ......
Page 835: ...G082...
Page 836: ......
Page 846: ......
Page 848: ......
Page 882: ......
Page 883: ...TECHNICAL SERVICE BULLETINS...
Page 925: ...FIRMWARE HISTORY...
Page 926: ......
Page 1077: ...FIRMWARE HISTORY...