Section 4 — Measurement Types and their Uses
64
Cross Channel Phase
Phase analysis is an effective way to diagnose machine faults such as
misalignment, resonance, soft foot, and looseness. Phase analysis is also
useful for distinguishing faults that look like imbalance but are actually
caused by something else. For example, misalignment can show up at
1X RPM, similar to imbalance. Knowledge of the phase relationships of
various machine faults will help confirm the existence of a specific
machine fault and help prevent misdiagnosis.
Cross Channel Phase is a convenient method of taking phase
measurements. It does NOT require the use of a tachometer or reflective
tape. Instead, phase is measured between two sensors.
NOTE: When taking measurements, be aware of the direction each
sensor is facing. If you are measuring across the coupling in the
axial direction, you will probably turn the sensors in opposite
directions, thereby introducing an additional 180° phase change.
Remember to take this into consideration when analyzing the
phase measurements.
Summary of Contents for SCOUT100-Ex
Page 18: ...Section 1 Introduction 7 Installation Control Drawing for Hazardous Locations ...
Page 20: ...Section 1 Introduction 9 Installation Control Drawing GE2214VBX for ATEX Hazardous Locations ...
Page 21: ...Section 1 Introduction 10 IECEx ATEX Declaration of Conformity ...
Page 40: ...Section 2 Instrument Fundamentals 29 Viewing hint labels Accessing more detailed help ...
Page 44: ...Section 2 Instrument Fundamentals 33 Using the advanced options ...
Page 54: ...Section 3 Sensors 43 Selecting the appropriate voltage for your tachometer and machine ...
Page 85: ...Section 4 Measurement Types and their Uses 74 Selecting the required parameter settings ...
Page 111: ...Section 4 Measurement Types and their Uses 100 Using the keypad to enter measurements ...
Page 116: ...Section 4 Measurement Types and their Uses 105 Example of tracked measurement ...
Page 120: ...Section 4 Measurement Types and their Uses 109 Saving multi channel measurements ...
Page 124: ...Section 5 Set Measurement Options 113 Spectral lines submenu ...
Page 164: ...Section 8 Send and Receive Information 153 Transferring recordings to Ascent ...
Page 194: ...Section 9 Working with Routes 183 Linear Speed ...
Page 241: ...Section 11 Balancing Rotors 230 Splitting a weight ...
Page 247: ...Section 12 Balancing Walkthrough 236 Taking an initial reading ...