Section 12 — Balancing Walkthrough
240
For dual plane balancing, perform the same procedure
for Plane B — Attach a trial weight, enter its position, and
specify whether weight is being added or drilled out. If
you are removing trial weights, you must remove the
Plane A trial weight before you do the Plane B trial
reading.
Step 4
—
Balance Rotor
The
Balance Weight
menu displays when you complete the Initial and
Trial Readings. Your instrument displays the weight required to correct
the initial imbalance and the angular position at which it must be
attached.
To balance the rotor:
1.
Stop the machine
.
IMPORTANT
! If you are removing trial weights as you go, ensure
you do this before attaching your correction weight.
2.
Attach or remove the recommended correction weight as indicated
by your instrument.
3.
Proceed to
Trim Balance
.
For dual plane balancing, two sets of values will display.
Balancing the rotor
Summary of Contents for SCOUT100-Ex
Page 18: ...Section 1 Introduction 7 Installation Control Drawing for Hazardous Locations ...
Page 20: ...Section 1 Introduction 9 Installation Control Drawing GE2214VBX for ATEX Hazardous Locations ...
Page 21: ...Section 1 Introduction 10 IECEx ATEX Declaration of Conformity ...
Page 40: ...Section 2 Instrument Fundamentals 29 Viewing hint labels Accessing more detailed help ...
Page 44: ...Section 2 Instrument Fundamentals 33 Using the advanced options ...
Page 54: ...Section 3 Sensors 43 Selecting the appropriate voltage for your tachometer and machine ...
Page 85: ...Section 4 Measurement Types and their Uses 74 Selecting the required parameter settings ...
Page 111: ...Section 4 Measurement Types and their Uses 100 Using the keypad to enter measurements ...
Page 116: ...Section 4 Measurement Types and their Uses 105 Example of tracked measurement ...
Page 120: ...Section 4 Measurement Types and their Uses 109 Saving multi channel measurements ...
Page 124: ...Section 5 Set Measurement Options 113 Spectral lines submenu ...
Page 164: ...Section 8 Send and Receive Information 153 Transferring recordings to Ascent ...
Page 194: ...Section 9 Working with Routes 183 Linear Speed ...
Page 241: ...Section 11 Balancing Rotors 230 Splitting a weight ...
Page 247: ...Section 12 Balancing Walkthrough 236 Taking an initial reading ...