5.3 Host Commands
Table 5.8 Example of rewriting procedure of data 640K Bytes (A0000h Bytes)
of microcode
Transfer example 1:
1) CMD = 92h SN, SC = 0100h FR = 0lh
2) CMD = 92h SN, SC = 0100h FR = 0lh
3) CMD = 92h SN, SC = 0100h FR = 0lh
4) CMD = 92h SN, SC = 0100h FR = 0lh
5) CMD = 92h SN, SC = 0100h FR = 0lh
6) CMD = 92h SN, SC = 0000h FR = 07h
Transfer of 128 KB (0 to 127 KB) from the
beginning
Transfer from 128 to 255 KB
Transfer from 256 to 383 KB
Transfer from 384 to 511 KB
Transfer from 512 to 639 KB
Firmware rewriting execution
Transfer example 2:
1) CMD = 92h SN, SC = 0500h FR = 0lh
2) CMD = 92h SN, SC = 0000h FR = 07h
Transfer of 640 KB
Firmware rewriting execution
Transfer example 3:
1) CMD = 92h SN, SC = 0500h FR = 07h
Transfer of 640 KB and Firmware rewriting
execution
Transfer example 4:
1) CMD = 92h SN, SC = 0100h FR = 0lh
2) CMD = 92h SN, SC = 0100h FR = 0lh
3) CMD = 92h SN, SC = 0100h FR = 0lh
4) CMD = 92h SN, SC = 0100h FR = 0lh
5) CMD = 92h SN, SC = 0100h FR = 07h
Transfer of 128 KB (0 to 127 KB) from the
beginning
Transfer from 128 to 255 KB
Transfer from 256 to 383 KB
Transfer from 384 to 511 KB
Transfer from 512 to 639 KB and Firmware
rewriting execution
The Aborted Command error is reported if any of the following conditions is
satisfied: transferred microcode data is incorrect, firmware rewriting is specified
before microcode data is transferred, or the DOWNLOAD MICROCODE
command is not issued continuously when the transfer has been divided into
multiple transfers.
•
Error reporting conditions
(1) When the transferred Micro code data error occurs (ST = 51h, ER = 04h).
(2) When writing is specified though the data has not transferred yet.
(ST = 51h, ER = 04h).
(3) When the Sector Offset(CH,CL Field) specification is the transfer end the last
sector and is not consecutive by the command of Mode3
(ST = 51h, ER = 04h)
(4) When the SATA frame error occurs. (ST = 51h, ER = 14h).
(5) When detect the error other than the above mentioned.
(ST = 51h, ER = 04h).
C141-E280
5-45
Summary of Contents for MHZ2080BJ
Page 4: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 44: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 284: ...This page is intentionally left blank ...
Page 300: ...This page is intentionally left blank ...
Page 304: ...This page is intentionally left blank ...
Page 306: ...This page is intentionally left blank ...
Page 314: ...This page is intentionally left blank ...
Page 316: ...This page is intentionally left blank ...
Page 318: ......
Page 319: ......
Page 320: ......