8-9
Ch
ap. 8
SPECIFICA
T
IO
NS
Item Explanation
Co
n
tr
o
l
Analog output
Terminals [FM1] and [FM2]:
Output a selected signal with analog DC voltage (0 to +10 V) or analog DC current (4 to 20 mA)
Selectable output signals:
Output frequency (before slip compensation, after slip compensation), output current, output
voltage, output torque, load factor, input power, PID feedback amount, speed (PG feedback value),
DC link bus voltage, universal AO, motor output, calibration, PID command (SV), PID output
(MV)
Indica
tion
Running/stopping
Speed monitor (reference frequency (Hz), output frequency, motor speed, load shaft speed, line
speed, speed in %)
Output current, output voltage, torque calculation value, input power, PID command value, PID
feedback amount, PID output, load factor, motor output, torque current, flux command, analog
signal input monitor, input watt-hour
Life early warning, cumulative inverter run time, cumulative motor run time, input watt-hour,
number of startups
I/O checking, energy-saving monitor (input power, input power x coefficient (charges for input
power))
Trip mode
Trip history: Saves and displays the last 4 trip factors and their detailed description.
O
the
r fea
tur
es
Communications
RS-485 COM port 1 (for keypad connection), RS-485 COM port 2 (on terminal block), USB port
(provided on an optional remote keypad)
Protection against
momentary power failure
Upon detection of a momentary power failure lasting more than 15 ms, this function stops the
inverter output. If restart after momentary power failure is selected, this function invokes a restart
process if power is restored within a predetermined period (allowable momentary power failure
time).