![Fuji Electric FRENIC-MEGA Instruction Manual Download Page 127](http://html1.mh-extra.com/html/fuji-electric/frenic-mega/frenic-mega_instruction-manual_2341853127.webp)
5-8
Ch
ap
. 5
FUNCTION C
O
DES
F codes
E codes
C codes
P codes
H codes
A codes
b codes
r codes
J codes
d codes
U codes
y codes
Code Name
Data
setting
range
Cha
nge wh
e
n
ru
nning
Da
ta
c
opy
ing
Default
setting
Drive control
Refer
to
page:
V/f
PG
V/f
w/o
PG
w/
PG
Torque
control
70 (1070): Speed valid
(
DNZS
)
N Y Y Y Y 5-91
71 (1071): Speed agreement
(
DSAG
)
N Y Y Y N
72 (1072): Frequency (speed) arrival signal 3
(
FAR3
)
Y Y Y Y N
76 (1076): PG error detected
(
PG-ERR
)
N Y Y Y N
82 (1082): Positioning completion signal
(
PSET
)
N N N Y N
84 (1084): Maintenance timer
(
MNT
)
Y Y Y Y Y
98 (1098): Light alarm
(
L-ALM
)
Y Y Y Y Y
99 (1099): Alarm output (for any alarm)
(
ALM
)
Y Y Y Y Y
101 (1101): Enable circuit failure detected
(
DECF
)
Y Y Y Y Y
102 (1102): Enable input OFF
(
EN OFF
)
Y Y Y Y Y
105 (1105): Braking transistor broken
(
DBAL
)
Y Y Y Y Y
111 (1111): Customizable logic output signal 1
(
CLO1
)
Y Y Y Y Y
112 (1112): Customizable logic output signal 2
(
CLO2
)
Y Y Y Y Y
113 (1113): Customizable logic output signal 3
(
CLO3
)
Y Y Y Y Y
114 (1114): Customizable logic output signal 4
(
CLO4
)
Y Y Y Y Y
115 (1115): Customizable logic output signal 5
(
CLO5
)
Y Y Y Y Y
Setting the value in parentheses ( ) shown above assigns
a negative logic output to a terminal.
E30 Frequency Arrival (Hysteresis width) 0.0 to 10.0 Hz
Y Y
2.5
Y Y Y Y N 5-96
E31 Frequency Detection 1
(Level) 0.0 to 500.0 Hz
Y Y
60.0
Y Y Y Y Y
E32
(Hysteresis width) 0.0 to 500.0 Hz
Y Y
1.0
Y Y Y Y Y
E34 Overload Early Warning/Current
Detection (Level)
0.00 (Disable); Current value of 1% to 200% of the inverter
rated current
Y Y1
Y2
*2 Y Y Y Y Y 5-97
E35
(Timer) 0.01 to 600.00s
Y Y
10.00
Y Y Y Y Y
E36 Frequency Detection 2
(Level) 0.0 to 500.0 Hz
Y Y
60.0
Y Y Y Y Y 5-96
5-98
E37 Current Detection 2/
Low Current Detection
(Level)
0.00 (Disable); Current value of 1% to 200% of the inverter
rated current
Y Y1
Y2
*2 Y Y Y Y Y 5-97
5-98
E38
(Timer) 0.01 to 600.00 s
Y Y
10.00
Y Y Y Y Y
E40 PID Display Coefficient A
-999 to 0.00 to 9990
Y Y
100
Y Y Y Y N 5-98
E41 PID Display Coefficient B
-999 to 0.00 to 9990
Y Y
0.00
Y Y Y Y N
E42 LED Display Filter
0.0 to 5.0 s
Y Y
0.5
Y Y Y Y Y 5-99
E43 LED Monitor
(Item selection) 0: Speed monitor (select by E48)
3: Output current
4: Output voltage
8: Calculated torque
9: Input power
10: PID command
12: PID feedback amount
14: PID output
15: Load factor
16: Motor output
17: Analog input
23: Torque current (%)
24: Magnetic flux command (%)
25: Input watt-hour
Y Y
0 Y Y Y Y Y 5-100
E44
(Display when stopped) 0: Specified value 1: Output value
Y Y
0 Y Y Y Y Y 5-101
E45 LCD Monitor
(Item selection) 0: Running status, rotational direction and operation guide
1: Bar charts for output frequency, current and calculated
torque
Y Y
0 Y Y Y Y Y
E46
(Language selection) Type: TP-G1W-J1
0: Japanese
1: English
2: German
3: French
4: Spanish
5: Italian
Y Y
1
Y Y Y Y Y 5-102
E47
(Contrast control) 0 (Low) to 10 (High)
Y Y
5 Y Y Y Y Y
E48 LED Monitor
(Speed monitor item) 0: Output frequency 1 (Before slip compensation)
1: Output frequency 2 (After slip compensation)
2: Reference frequency
3: Motor speed in r/min
4: Load shaft speed in r/min
5: Line speed in m/min
7: Display speed in %
Y Y
0 Y Y Y Y Y 5-100
5-102
*2 The motor rated current is automatically set. See Table B (P03/A17/b17/r17).
Summary of Contents for FRENIC-MEGA