F codes
E codes
C codes
P codes
H codes
A codes
b codes
r codes
J codes
d codes
U codes
y codes
Code Name
Data
setting
range
Ch
ange wh
e
n
ru
nning
Da
ta
cop
yi
ng Default
setting
Drive control
Refer
to
page:
V/f
PG
V/f
w/o
PG
w/
PG
Torque
control
F23 Starting Frequency 1
0.0 to 60.0 Hz
Y
Y 0.5 Y Y Y Y N 5-59
F24
(Holding time) 0.00 to 10.00 s
Y
Y 0.00 Y Y Y Y N
F25 Stop Frequency
0.0 to 60.0 Hz
Y
Y 0.2 Y Y Y Y N
F26 Motor Sound
(Carrier frequency) 0.75 to 16 kHz (LD-mode inverters of 0.5 to 30 HP and
HD-mode ones of 0.5 to 100 HP)
0.75 to 10 kHz (LD-mode inverters of 40 to 100 HP and
HD-mode ones of 125 to 800 HP)
0.75 to 6 kHz (LD-mode inverters of 125 to 900 HP and
HD-mode ones of 900 and 1000 HP)
0.75 to 4 kHz (LD-mode inverters of 1000 HP)
0.75 to 2 kHz (MD-mode inverters of 150 to 800 HP)
Y
Y
2 Y Y Y Y Y 5-62
F27
(Tone) 0: Level 0 (Inactive)
1: Level
1
2: Level
2
3: Level
3
Y
Y 0
Y
Y
N
N
Y
F29 Analog Output [FM1]
(Mode
selection)
0: Output in voltage (0 to 10 VDC)
1: Output in current (4 to 20 mA DC)
Y
Y
0 Y Y Y Y Y 5-63
F30
(Voltage adjustment) 0% to 300%
Y*
Y 100 Y Y Y Y Y
F31
(Function) Select a function to be monitored from the followings.
0: Output frequency 1 (before slip compensation)
1: Output frequency 2 (after slip compensation)
2: Output
current
3: Output
voltage
4: Output
torque
5: Load
factor
6: Input
power
7: PID
feedback
amount
(PV)
8: PG
feedback
value
9: DC link bus voltage
10: Universal AO
13: Motor output
14: Calibration (+)
15: PID command (SV)
16: PID output (MV)
Y
Y
0 Y Y Y Y Y
17: Positional deviation in synchronous running
F32 Analog Output [FM2]
(Mode
selection)
0: Output in voltage (0 to 10 VDC)
1: Output in current (4 to 20 mA DC)
Y
Y
0 Y Y Y Y Y
F34
(Voltage adjustment) 0% to 300%
Y*
Y 100 Y Y Y Y Y
F35
(Function) Select a function to be monitored from the followings.
0: Output frequency 1 (before slip compensation)
1: Output frequency 2 (after slip compensation)
2: Output
current
3: Output
voltage
4: Output
torque
5: Load
factor
6: Input
power
7: PID
feedback
amount
(PV)
8: PG
feedback
value
9: DC link bus voltage
10: Universal AO
13: Motor output
14: Calibration (+)
15: PID command (SV)
16: PID output (MV)
Y
Y
0 Y Y Y Y Y
17: Positional deviation in synchronous running
F37 Load Selection/
Auto Torque Boost/
Auto Energy Saving Operation 1
0: Variable torque load
1: Constant
torque
load
2: Auto torque boost
3: Auto energy saving
(Variable torque load during ACC/DEC)
4: Auto energy saving
(Constant torque load during ACC/DEC)
5: Auto
energy
saving
(Auto torque boost during ACC/DEC)
N
Y 1
Y
Y
N
Y
N
5-64
F38 Stop Frequency
(Detection mode) 0: Detected speed
1: Reference speed
N
Y 0
N
N
N
Y
N
5-59
F39
(Holding Time) 0.00 to 10.00 s
Y
Y 0.00 Y Y Y Y N 5-66
F40 Torque Limiter 1-1
-300% to 300%; 999 (Disable)
Y
Y 999 Y Y Y Y Y 5-66
F41
1-2
-300% to 300%; 999 (Disable)
Y
Y 999 Y Y Y Y Y
F42 Drive Control Selection 1
0: V/f control with slip compensation inactive
1: Dynamic torque vector control
2: V/f control with slip compensation active
3: V/f control with speed sensor
4: Dynamic torque vector control with speed sensor
5: Vector control without speed sensor
6: Vector control with speed sensor
N
Y
0 Y Y Y Y Y 5-73