![Fuji Electric FRENIC-MEGA Instruction Manual Download Page 285](http://html1.mh-extra.com/html/fuji-electric/frenic-mega/frenic-mega_instruction-manual_2341853285.webp)
5-166
Ch
ap
. 5
FUNCTION C
O
DES
F codes
E codes
C codes
P codes
H codes
A codes
b codes
r codes
J codes
d codes
U codes
y codes
d60
d71 to d78
Command (Pulse Rate Input) (Encoder pulse resolution)
Synchronous Operation
These function codes specify various parameters required for synchronous operation. For details, refer to the PG Interface
Card instruction manual.
d70
Speed Control Limiter
d70 specifies a limiter for the PI value output calculated in speed control sequence under V/f control with speed sensor or
dynamic torque vector control with speed sensor.
A PI value output is within the "slip frequency
×
maximum torque (%)" in a normally controlled state.
If an abnormal state such as a temporary overload arises, the PI value output greatly fluctuates and it may take a long time
for the PI value output to return to the normal level. Limiting the PI value output with d70 suppresses such abnormal
operation.
Data setting range: 0 to 100 (%) (assuming the maximum frequency as 100%)
Summary of Contents for FRENIC-MEGA
Page 36: ...2 6 Unit inch mm Refer to Section 2 3 3 9...