8-4
HD (High Duty)-mode inverters for heavy load
(0.5 to 75 HP)
Item Specifications
Type (FRN_ _ _G1S-4U) F50
001
002
003
005
007
010
015
020
025
030
040
050
060
075
100
Nominal applied motor
(HP)
*1
(Output rating)
0.5 1 2 3 5 7.5
7.5
10
15
20
25
30
40
50
60
75
Ou
tpu
t r
a
ti
ng
s
Rated capacity (kVA)
*2
1.2 2.0
3.2 4.4 7.2 11
11
15
20
25
31
36
48
60 73 89
Rated voltage (V)
*3
Three-phase 380 to 480 V (with AVR function)
Rated current (A)
1.5
2.5
4
5.5
9
13.5
13.5
18.5
24.5
32
39
45
60
75
91
112
Overload capability
150%-1 min, 200%-3.0 s
Inpu
t po
w
e
r Voltage, frequency
380 to 480 V, 50/60 Hz
Allowable
voltage/frequency
Voltage: +10 to -15% (Interphase voltage unbalance: 2% or less)
*4
, Frequency: +5 to -5%
Required capacity
(with DCR) (kVA)
*5
0.6 1.2
2.1 3.2 5.3 7.4
7.4
9.9
15.0
20.0
25.0
29.0
40.0
48.0
58.0
71.0
Brak
ing
Torque (%)
*6
150%
100%
20%
10 to 15%
Braking transistor
Built-in
–
Built-in braking resistor
Built-in
–
Braking time (s)
5 s
–
Duty cycle (%ED)
5
3
5
3
2
3
3
2
–
DC reactor (DCR)
Option
Standard
*7
Applicable safety
standards
UL508C, C22.2 No.14, EN61800-5-1:2007
Enclosure (IEC60529)
IP20, UL open type
IP00, UL open type
Cooling method
Natural cooling
Fan cooling
Weight / Mass
lbs (kg)
3.8
(1.7)
4.4
(2.0)
5.7
(2.6)
6.0
(2.7)
6.6
(3.0)
14
(6.5)
14
(6.5)
14
(6.5)
13
(5.8)
21
(9.5)
21
(9.5)
22
(10)
55
(25)
57
(26)
68
(31)
73
(33)
(100 to 900 HP)
Item Specifications
Type (FRN_ _ _G1S-4U) 125
150
200
250
300
350
450
500
600
700
800
900
1000
Nominal applied motor
(HP)
*1
(Output rating)
100 125
150 200 250 300
350
400
450
500
600
800
900
O
u
tput r
a
ti
ngs
Rated capacity (kVA)
*2
120 140
167 202 242 300
330
414
466
518
590
765
932
Rated voltage (V)
*3
Three-phase 380 to 480 V (with AVR function)
Rated current (A)
150
176
210
253
304
377
415
520
585
650
740
960
1170
Overload capability
150%-1 min
,
200%-3.0 s
Inpu
t po
w
e
r Voltage, frequency
380 to 440 V, 50 Hz
380 to 480 V, 60 Hz
Allowable
voltage/frequency
Voltage: +10 to -15% (Interphase voltage unbalance: 2% or less)
*4
, Frequency: +5 to -5%
Required capacity
(with DCR) (kVA)
*5
96 114
140 165 199 248
271
347
388
436
489
611
773
B
rak
in
g
Torque (%)
*6
10 to 15%
Braking transistor
–
Built-in braking resistor –
Braking time (s)
–
Duty cycle (%ED)
–
DC reactor (DCR)
Standard
*7
Applicable safety
standards
UL508C, C22.2 No.14, EN61800-5-1:2007
Enclosure (IEC60529)
IP00, UL open type
Cooling method
Fan cooling
Weight / Mass
lbs (kg)
93
(42)
137
(62)
141
(64)
207
(94)
216
(98)
284
(129)
309
(140)
540
(245)
540
(245)
728
(330)
728
(330)
1169
(530)
1169
(530)
*1 US-4P standard induction motor
*2 Rated capacity is calculated assuming the rated output voltage as 230 V for 230 V series and 460 V for 460 V series.
*3 Output voltage cannot exceed the power supply voltage.
*
4
3)
-
61800
(IEC
67
×
(V)
voltage
average
phase
-
Three
(V)
voltage
Min.
-
(V)
voltage
Max.
(%)
unbalance
Voltage
=
If this value is 2 to 3%, use an optional AC reactor (ACR).
*5 Required when a DC reactor (DCR) is used.
*6 Average braking torque for the motor running alone, without external braking resistor. (It varies with the efficiency of the motor.)
*7 The FRN100G1S-4U or higher type comes with a DC reactor (DCR).