![Fuji Electric FRENIC-MEGA Instruction Manual Download Page 165](http://html1.mh-extra.com/html/fuji-electric/frenic-mega/frenic-mega_instruction-manual_2341853165.webp)
5-46
Ch
ap
. 5
FUNCTION C
O
DES
F codes
Under vector control without speed sensor
Under vector control with speed sensor
Acceleration/deceleration time
Acceleration/
deceleration time
Function code
Switching factor of acceleration/deceleration time
(
Refer to the descriptions of E01 to E07.)
ACC time DEC time
Acceleration/
deceleration time 1
F07 F08
RT1
RT2
The combinations of ON/OFF states of the two
terminal commands
RT2
and
RT1
offer four
choices of acceleration/deceleration time 1 to 4.
(Data = 4, 5)
If no terminal command is assigned, only the
acceleration/deceleration time 1 (F07/F08) is
effective.
OFF
OFF
Acceleration/
deceleration time 2
E10 E11
OFF
ON
Acceleration/
deceleration time 3
E12 E13
ON
OFF
Acceleration/
deceleration time 4
E14 E15
ON
ON
At jogging
operation
H54 H55
When the terminal command
JOG
is ON, jogging operation is
possible. (Data = 10)
(
Refer to the description of C20.)
At forced stop
-
H56
When the terminal command
STOP
is OFF, the motor decelerates
to a stop in accordance with the deceleration time for forced stop
(H56). After the motor stops, the inverter enters the alarm state
with the alarm
er6
displayed. (Data = 30)