Endpoint buffer size register
setting (binary)
Non-isochronous
endpoint
Isochronous
endpoint
0000
8 bytes
16 bytes
0001
16 bytes
32 bytes
0010
32 bytes
48 bytes
0011
64 bytes
64 bytes
0100
-
96 bytes
0101
-
128 bytes
0110
-
160 bytes
0111
-
192 bytes
1000
-
256 bytes
1001
-
320 bytes
1010
-
384 bytes
1011
-
504 bytes
1100-1111
-
-
Table 2.116 Endpoint Maximum Packet Size
Note:
504 is the maximum byte count as there are 1024 bytes in total and 8 bytes IN and OUT
packets for control endpoint 0 must always be reserved.