506
Da
ta
Com
m
uni
c
a
tio
n
Operation when parameter is omitted
AT+CGDCONT=
Clears all <cid> settings. Resets <cid>=1 setting to its default value.
AT+CGDCONT=<cid>
Clears specified <cid> setting. Resets <cid>=1 setting to its default value.
AT+CGDCONT=?
Displays list of values that can be set.
AT+CGDCONT?
Displays current settings.
J
Command name: +CGEQMIN= [parameter]
Overview
Registers criterion determining whether to permit QoS (Quality of Service) sent from the network when
establishing PPP packet transmission.
The command execution examples below describe the four possible setting patterns.
Not stored in FOMA terminal’s memory using AT&W commands. Not reset with AT&F or ATZ commands.
Syntax
AT+CGEQMIN=[<cid> [,, <Maximum bitrate UL> [, <Maximum bitrate DL>]]]
o
Parameter description
<cid>
*
:
1 to 10
<Maximum bitrate UL>
*
:
None (initial setting) or 64
<Maximum bitrate DL>
*
:
None (initial setting) or 384
<cid> is a number for managing hosts (APNs) used for packet transmission, registered in the FOMA
terminal. It can be set between 1 and 10 in the FOMA.
Maximum bitrate UL
and
Maximum bitrate DL
set the minimum uplink and downlink transmission speed (kbps) between the FOMA and base station.
When set to
None
(default setting), all speeds are permitted. Note that when set to
64
or
384
,
connections established under these speeds are not permitted, so packet transmission connection may
not be established.
Execution example
Set using the following four patterns. Setting (1) is the initial setting for all cid.
(1)
Command permitting all uplink/downlink speeds (for <cid>=2)
AT+CGEQMIN=2
o
OK
(2)
Command permitting uplink speeds of at least 64 kbps, and downlink speeds of at least 384 kbps
(for <cid>=3)
AT+CGEQMIN=3,,64,384
o
OK
(3)
Command permitting only uplink speeds of at least 64 kbps, and all downlink speeds (for <cid>=4)
AT+CGEQMIN=4,,64
o
OK
(4)
Command permitting all uplink speeds, and only downlink speeds of at least 384 kbps (for <cid>=5)
AT+CGEQMIN=5,,,384
o
OK
Operation when parameter is omitted
AT+CGEQMIN=
Clears all <cid> settings.
AT+CGEQMIN=<cid>
Returns specified <cid> setting to default setting.
AT+CGEQMIN=?
Displays list of values that can be set.
AT+CGEQMIN?
Displays current settings.
dv22̲e.book Page 506 Monday, February 14, 2005 4:58 PM
Summary of Contents for SH700i
Page 50: ...LMEMO9 48 dv22 e book Page 48 Monday February 14 2005 4 58 PM ...
Page 92: ...LMEMO9 90 dv22 e book Page 90 Monday February 14 2005 4 58 PM ...
Page 244: ...LMEMO9 242 dv22 e book Page 242 Monday February 14 2005 4 58 PM ...
Page 581: ...LMEMO9 579 dv22 e book Page 579 Monday February 14 2005 4 58 PM ...