Biomedical Test System
Customize Your medTester
6
6-15
Resetting Autosequences to Default Settings
You can always return medTester 5000C autosequences to the default settings
by reinitializing the medTester. Safety autosequences require you to indicate
whether you want to include power-off tests, reverse polarity tests, and open
neutral tests. To access this feature for the safety autosequences, press the
right arrow on the custom menu display, and enter the menu commands:
SAFETY
F1
INIT
F3
To return to the default settings for other types of autosequences, such as
defibrillation or IV pump, select the desired type from the custom
initialization menu. To initialize all custom features to default, press the right
arrow from the custom initialization menu, then press:
OTHER
F4
Pressing
other
sets all customized features to the factory default settings. For
more information about these settings, see
Factory Default Settings
in Chapter 2,
Installation
.
Printing Your medTester 5000C Configuration
With a printer connected to the printer port on the back panel of your
medTester 5000C, you can print out your configuration of the medTester by
entering these commands:
F4
Customize medTester 5000C Options
The descriptions of autosequence customizing features in this chapter apply
as well to other autosequences. If your medTester 5000C includes the
defibrillator and/or IV pump modules, you can customize those
autosequences tool. For more information see:
•
Chapter 9,
Defibrillator Module.
•
Chapter 10,
IV Pump Module.
•
Chapter 14,
ESU Module.
•
Chapter 15,
SPO2 Module.
Summary of Contents for medTester 5000C Operators
Page 6: ......
Page 32: ...medTester 5000C Operators Manual 1 20...
Page 40: ...medTester 5000C Operators Manual 2 8...
Page 46: ...medTester 5000C Operators Manual 3 6...
Page 59: ...Biomedical Test System Manual Tests 4 4 13 Figure 4 1 Three Types of Line Voltage Measurements...
Page 60: ...medTester 5000C Operators Manual 4 14 Figure 4 2 Case External Leakage...
Page 61: ...Biomedical Test System Manual Tests 4 4 15 Figure 4 3 Case Internal Leakage...
Page 62: ...medTester 5000C Operators Manual 4 16 Figure 4 4 External Leakage Current...
Page 64: ...medTester 5000C Operators Manual 4 18 Figure 4 6 ECG Interlead Leakage...
Page 66: ...medTester 5000C Operators Manual 4 20 Figure 4 8 Equipment Load Current...
Page 67: ...Biomedical Test System Manual Tests 4 4 21 Figure 4 9 Power Cord Resistance Test...
Page 68: ...medTester 5000C Operators Manual 4 22 Figure 4 10 External Resistance...
Page 70: ...medTester 5000C Operators Manual 4 24...
Page 108: ...medTester 5000C Operators Manual 6 16...
Page 114: ...medTester 5000C Operators Manual 7 6...
Page 124: ...medTester 5000C Operators Manual 8 10...
Page 178: ...medTester 5000C Operators Manual 11 14...
Page 196: ...medTester 5000C Operators Manual 12 18...
Page 210: ...medTester 5000C Operators Manual 13 14...
Page 256: ...medTester 5000C Operators Manual 15 28...