Follow directions, such as cycling power after reprogramming the scanner.
The scanner remains programmed after cycling power on the scanner and/or
the medTester.
Of the medTester autosequence prompts, you can configure eleven of them
to accept multiple labels when entering data from a bar code reader. The
eleven include the following:
medTester Bar Code Configurable Prompts
Prompt Name
1 OP
CODE
2 TYPE
3 MANF
4 LOC
5 MODEL
6 SERIAL
#
7 CONTROL
#
8 PHYSICAL
INSPECTION
9
PERFORMANCE WAVE COMMENTS
10 COMMENTS
11
NEXT TEST DUE DATE
Each bar code entry response to the prompt can include either single or
multiple labels. To access this customization feature, press the right arrow on
the customization menu display and select:
BARCODE
F2
For each prompt number and type, select either
F2
to accept a single
barcode label for data entered at this prompt, or select
F3
to accept
multiple label data entry. For example, you could enable multiple entry
input for prompt 10,
comments
. One bar code could indicate that the EUT
is dirty. Another could indicate that the EUT is greasy or dented. Any or
all of these conditions could be scanned into the comments section from
multiple bar code entries.
All of these entries are called strings, and multiple bar codes can combine
to form a string. A string ending in three spaces terminates the whole
string.
When finished with one field, you press
F4
to move to the next field
prompt or
F5
to end customization of these prompts.
Summary of Contents for medTester 5000C Operators
Page 6: ......
Page 32: ...medTester 5000C Operators Manual 1 20...
Page 40: ...medTester 5000C Operators Manual 2 8...
Page 46: ...medTester 5000C Operators Manual 3 6...
Page 59: ...Biomedical Test System Manual Tests 4 4 13 Figure 4 1 Three Types of Line Voltage Measurements...
Page 60: ...medTester 5000C Operators Manual 4 14 Figure 4 2 Case External Leakage...
Page 61: ...Biomedical Test System Manual Tests 4 4 15 Figure 4 3 Case Internal Leakage...
Page 62: ...medTester 5000C Operators Manual 4 16 Figure 4 4 External Leakage Current...
Page 64: ...medTester 5000C Operators Manual 4 18 Figure 4 6 ECG Interlead Leakage...
Page 66: ...medTester 5000C Operators Manual 4 20 Figure 4 8 Equipment Load Current...
Page 67: ...Biomedical Test System Manual Tests 4 4 21 Figure 4 9 Power Cord Resistance Test...
Page 68: ...medTester 5000C Operators Manual 4 22 Figure 4 10 External Resistance...
Page 70: ...medTester 5000C Operators Manual 4 24...
Page 108: ...medTester 5000C Operators Manual 6 16...
Page 114: ...medTester 5000C Operators Manual 7 6...
Page 124: ...medTester 5000C Operators Manual 8 10...
Page 178: ...medTester 5000C Operators Manual 11 14...
Page 196: ...medTester 5000C Operators Manual 12 18...
Page 210: ...medTester 5000C Operators Manual 13 14...
Page 256: ...medTester 5000C Operators Manual 15 28...