Replace the diamond orifice
Where used
Mach 500 · Mach 300 · Mach 200 · Mach 100
Recommended maintenance interval
As required
Tools
Torque wrench with crows foot attachment
Supplies
Blue Lubricant
Clean, lint-free applicator
Clean, lint-free cloth
To replace the diamond orifice, do the following:
1. Make sure that the high-pressure pump is off and bleed down all pressure from the system.
2. Pull firmly on the abrasive feed line to remove it from the cutting head, and then open the
cutting head clamp.
3. Using a 1-1/8 in. wrench on the mixing chamber and a 7/8 in. wrench on the nozzle body,
separate the mixing chamber and nozzle body.
4. Tap the mixing chamber upside down on a table to remove the orifice assembly. If necessary,
lightly pry on the mount with a screwdriver.
5. Clean the mixing chamber to remove abrasive and debris.