7. Loosen the coupling that attaches the pneumatic manifold to the vessel, and then set the
manifold aside.
8. Disconnect the cable from the solenoid mounted on the pinch valve.
9. Position wooden blocking between the floor and the abrasive outlet port to support the vessel
during removal.
10.
Remove the four M16 hex screws, and then lower the vessel onto the wooden blocking.
© 2021 Flow International Corp.