Failed DCF bellows
Moisture leaking inside the PCB could cause damage and/or loss of functionality. Call Flow
Service. The PCB is seal against accidental opening or tampering.
DO NOT
open this
component. if you have opened the PCB, it must be replaced with a new unit.
Erratic readings, false collision signals, or accuracy issues
If the device is near an external magnetic interference source, this will cause a wide range of
problems. Look for a source of magnetic interference, and remove or shield the device from it.
DCF makes contact with the material clamps
Make sure the clamps are placed such that the DCF does not come in contact with them. This
also indicates the device is not calibrated correctly. Calibrate the DCF, making sure to follow all
steps in the instructions.
Feedrate errors
This indicates the device is not calibrated correctly. Calibrate the DCF, making sure to follow all
steps in the instructions.
Abrasive blast from the nozzle
The foot brush is designed to contain abrasive blast from the cutting nozzle. Worn brushes can
affect cutting accuracy. Inspect the foot brush and replace it if approximately one-third of the
bristles are gone or if the length of the bristles have been reduced by 1 mm.
Mixing tubes keep breaking
This indicates the device is not calibrated correctly. Calibrate the DCF, making sure to follow all
steps in the instructions.
© 2021 Flow International Corp.
Retrieved from Flow KB on April 14, 2021 PST
Ancillary option: Dynamic Contour Follower
Summary of Contents for MACH 300
Page 1: ...MACH 300 SYSTEM MANUAL Includes Ancillary Options M 810 REV C en APRIL 2021...
Page 28: ...View 2 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Page 29: ...View 3 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Page 107: ...ANCILLARY OPTIONS For Mach 300...