![background image](http://html1.mh-extra.com/html/flow/mach-300/mach-300_manual_2307753073.webp)
Calibrate the Dynamic Waterjet height sensor
Where used
Mach 500 ……………… Dynamic Waterjet
Mach 300 ……………… Dynamic Waterjet
Recommended interval
Weekly
Tools
0.100 in. shim
Supplies
Non-pliable material such as a solid sheet of metal
To calibrate the height sensor, do the following:
1. Put your material on the work platform, and then clean its surface to ensure contact with the
height sensor during calibration.
2. Put a 0.100 in. shim in the middle of the material.
3. Jog the machine to the center of the material with the arrow keys on the keyboard.
4. Open a .ord file in FlowCUT, verify Dynamic Waterjet is turned on, and then select
Run
Machine
.
5. Lower the Z-axis until the mixing tube “just touches” the surface of the shim.
6. In the
Homing
dialog box, click
Set current position as user home
.
7. Select the
Enable Height Sensor
checkbox.
8. Select
Option Component
, and then scroll until you see
(1): Calibrate height
sensor
. Select
1
, and the select
Close
.
© 2021 Flow International Corp.
Retrieved from Flow KB on April 15, 2021 PST
Calibrations and alignments
Summary of Contents for MACH 300
Page 1: ...MACH 300 SYSTEM MANUAL Includes Ancillary Options M 810 REV C en APRIL 2021...
Page 28: ...View 2 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Page 29: ...View 3 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Page 107: ...ANCILLARY OPTIONS For Mach 300...