Clean the linear rails
Where used
Mach 500 · Mach 300 · Mach 200 · Mach 100
Recommended maintenance interval
Every 120 hours of operation
Supplies
• Clean, lint-free cloth
• CRC Technical Grade 3-36® Multi-purpose Precision Lubricant or equivalent cleaner
To clean the linear rails, do the following:
1. Pull back all the bellows.
2. Spray a light, even layer of cleaner on the rails.
3. Allow time for the cleaner to penetrate the dirt and grease, and then remove it with a clean, lint-
free cloth.
4. Put the bellows back in place.
© 2021 Flow International Corp.