Set up UltraPierce in FlowCUT
To set up the device in FlowCut, do the following:
1. Go to
Setup
>
Jet
. In the dialog box, select
Pierce First
.
2. Under
Pierce
routine, choose a routine.
3. Under
Vacuum
control, choose an option.
4. Under
ON procedure
, enter the time (in seconds) of each dwell, and then select
Abrasive on
first, then jet on
to minimize delamination.
5. Under
OFF
procedure, enter the time (in seconds) of each dwell.
6. In the
Pierce time
box, enter the length of time.
7. Select
Save as Default
or
OK
.