![background image](http://html1.mh-extra.com/html/flow/mach-300/mach-300_manual_2307753156.webp)
Cleaning the pump
Where used
ATS 2200 and ATS 4400
During cross flow separation and dewatering operations, mud flowing through the pump may build up on
the internal parts and can harden (particularly if left overnight or weekends). To prevent the buildup of
mud from interfering with the operation of the pump, use the supplied hose rinse adapter to connect a
standard garden hose to the CAM lock inlet (top) of the pump. Performing the steps below will ensure
trouble free operation of your pump for many years.
To clean the pump, do the following:
1. Connect a garden hose to the pump rinse adapter.
2. Disconnect the cross-flow separator (or the dewatering) hose from the top of the pump.
3. Connect the pump rinse adapter to the inlet of the pump, and then turn on the water to the
hose.
Make sure the suction/discharge nozzle is placed in the catcher tank as the water
discharged from the pump will flow out the end of the discharge line (along with any material
being flushed from the pump)
4. Run the hose until clear water flows from the discharge hose into the catcher tank.
Turn on the air supply valve enough to cycle the pump a few times to ensure a complete
flush.
5. Turn off the water and reconnect the cross-flow separator hose to the pump inlet.
© 2021 Flow International Corp.
Retrieved from Flow KB on April 14, 2021 PST
Ancillary option: Abrasive Transfer System (ATS)
Summary of Contents for MACH 300
Page 1: ...MACH 300 SYSTEM MANUAL Includes Ancillary Options M 810 REV C en APRIL 2021...
Page 28: ...View 2 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Page 29: ...View 3 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Page 107: ...ANCILLARY OPTIONS For Mach 300...