Stop or end the part program
Where used
Mach 500 · Mach 300 · Mach 200 · Mach 100
Start, restart, or resume the part program
When you stop the part program, the high-pressure water stream and abrasive flow also stop.
• To stop the part program, select
Cycle Stop
or press the Spacebar.
◦ (Mach 500 , Mach 300, and Mach 200 only) Additionally, you can press the Cycle Stop
button on the roll-around console.
• To restart the part program after it was stopped, select
Cycle Start
.
• To resume the part program after it was stopped, do the following:
1. On the
Cutting
menu, select
Cut from a point
.
2. Click on the point in the drawing "just before" the location where the program stopped.
3. When you receive the “Jet will move to this point and start the cut by USING CURRENT
HOME POSITION” message, select
Yes
.
End, restart, or resume the part program
When you end the part program, the high-pressure water stream and abrasive flow stop. If you selected
the
Automatically turn off pump after cutting
check box in FlowCUT during setup, the pump also
stops.
• To end the part program, press the Esc key.
• To restart the part program after you end it, start the pump and then select
Cycle Start
.
• To resume the part program after you end it, do the following:
1. Start the pump.
2. On the
Cutting
menu, select
Cut from a point
.
3. Click the point in the drawing "just before" the location where the program stopped.
4. When you receive the “Jet will move to this point and start the cut by USING CURRENT
HOME POSITION” message, select
Yes
.
© 2021 Flow International Corp.
Retrieved from Flow KB on April 14, 2021 PST
Get started: Operation Basics · Mach 300
Summary of Contents for MACH 300
Page 1: ...MACH 300 SYSTEM MANUAL Includes Ancillary Options M 810 REV C en APRIL 2021...
Page 28: ...View 2 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Page 29: ...View 3 2021 Flow International Corp Retrieved from Flow KB on April 12 2021 PST Safety...
Page 107: ...ANCILLARY OPTIONS For Mach 300...