Clean the diamond orifice and nozzle nut
Where used
Mach 500 · Mach 300 · Mach 200 · Mach 100
Recommended maintenance interval
Every 250 hours or any time you experience degraded waterjet quality.
To clean the diamond orifice or nozzle nut, do the following:
1. Soak the part in an ultrasonic cleaning bath for approximately 5–10 minutes and then remove
the part from the ultrasonic bath and thoroughly dry with pressurized air.
2. Use a high-power camera or microscope to inspect the part. Verify that no residue or debris
remains.
© 2021 Flow International Corp.
Retrieved from Flow KB on April 15, 2021 PST
Cutting head maintenance