Calibrate UltraPierce
Recommended interval
As required; calibrate when the vacuum unit does not produce enough vacuum for correct operation.
Tools
Vacuum Assist tool kit · 014578-1
To calibrate the device, do the following:
1. Shut down the machine.
2. Disconnect the abrasive line from the abrasive inlet port.
3. Assemble vacuum gauge (including adapter, coupling, and tubing) and then connect it to
the open abrasive inlet port.
4. Disconnect the exhaust hose from the eductor sleeve.