Ultrasound Technologies 

Operating Instructions

PD1+

fetal pocket doppler with FHR display

PD1

fetal pocket doppler

Summary of Contents for PD1 series

Page 1: ...Ultrasound Technologies Operating Instructions PD1 fetal pocket doppler with FHR display PD1 fetal pocket doppler...

Page 2: ...e LCD display The PD1 also has an RS232 data port for the transfer of data to a PC to review the fetal heart rate traces The instrument is supplied complete with the following Doppler Instrument with...

Page 3: ...the PD1 press the switch located on the front of the PD1 unit B The PD1 will stay on for approximately 5 minutes or until the on off switch is pressed again With the unit on the volume can be adjuste...

Page 4: ...on and fetal heart rate F A battery icon C is displayed when the battery requires changing The fetal pulse icon G flashes at approximately the same rate as the detected fetal heart Serial RS232 connec...

Page 5: ...PD1 3 digit FHR LCD display Battery low icon and FHR pulse icon Power Supply Battery MN1604 PP3 9V Alkaline Manganese Expected battery life 9 hours of use PD1 5 hours PD1 Output Headset Audio output t...

Page 6: ...abdomen Tilt the transducer slowly until the fetal heart is heard in the loudspeaker or headset in early pregnancy the headset helps to eliminate ambient noise making it easier to detect the weaker si...

Page 7: ...dows supported printers Details of the use of UltraTrace2 are included in the UltraTrace2 operating manual For more information contact your supplier CARE OF YOUR PD1 OR PD1 DOPPLER After each use car...

Page 8: ...se have available the instrument type and serial number The serial number can be found inside the battery compartment SERVICE A service manual for this equipment which includes circuit diagrams parts...

Page 9: ...assure that it is used in such an environment Emission Test Compliance Electromagnetic Environment RF emissions Group 1 The PD1 series pocket doppler CISPR 11 uses RF energy only for its internal func...

Page 10: ...P 800MHz to 2 5GHz Portable and mobile RF communications equipment should be used no closer to any part of the PD1series pocket doppler including cables than the recommended separation distance calcul...

Page 11: ...he measured field strength in the location in which the PD1 series pocket doppler is used exceeds the applicable RF compliance level shown above the PD1 series pocket doppler should be observed to ver...

Page 12: ...according to frequency of transmitter m 150KHz to 80MHz to 800MHz to 80MHz 800MHz 2 5GHz d 1 2 P d 1 2 P d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 11 Ra...