6-5
CrossPoint 450 Plus and MAV Plus Switchers • HTML Operation
System Configuration Page
The CrossPoint 450 Plus or MAV Plus switcher downloads the System
Configuration page (figure 6-4) when you click the Configuration tab. The screen
consists of fields in which you can view and edit IP administration and system
settings. The Email Settings and Passwords pages can be accessed by clicking the
appropriate link. See appendix A, Ethernet Connection, for basic information about
IP addresses and subnetting.
Access to the IP settings using the Ethernet port is not password protected.
Ensure only knowledgeable and qualified personnel access the switcher using
HTML control.
Select Passwords.
Refresh.
Select Firmware Upgrade.
Select Email Settings.
Figure 6-4
—
System Configuration page
On password-protected connections, there are two levels of protection:
administrator and user. Administrators have full access to all switching capabilities
and editing functions. Users can create ties, create and recall presets, set RGB and
audio mutes, and view all settings with the exception of passwords.
•
Ethernet connection to the switcher, either entering SIS commands (see
chapter 4, Programmer’s Guide) or using the Extron Matrix S Control
Program (see chapter 5, Matrix Software) is password protected.
•
Connection via the RS-232/RS-422 port is not password protected.