Command/response table for SIS commands (Cont’d)
Command
ASCII Command Response
Additional description
(host to switcher)
(switcher to host)
Names
Write
global preset name
Esc X11
,
X23
NG
Nmg
X11
,
X23
Example:
Esc
1,Security 1NG
Nmg01,Security 1
Name global preset 1 “Security 1”.
Read
global preset name
Esc X11
NG
X23
Example:
Esc
2NG
Security 2
Write
room name
Esc
X8
,
X23
NR
Nmr
X8
,
X23
Example:
Esc
1,Classrm 1NR
Nmr01,Classrm 1
Name room “Classrm 1”.
Read
room name
Esc
X8
NR
X23
Write
room preset name
Esc
X8
*
X12
,
X23
NP
Nmp
X8
*
X12
,
X23
Example:
Esc
1*3,Podium_DVDNP
Name room 1, preset 3
Nmp01*03,
X23
“Podium_DVD”.
Read
room preset name
Esc
X8
*
X12
NP
X23
•
If a preset is unassigned, then
X23
displays [unassigned].
•
If a global preset is saved, but not yet named, the default name is Preset
X11
.
•
If a room preset is saved, but not yet named, the default name is Rm
X8
Prst
X12
.
Write
input name
Esc
X1
,
X23
NI
Nmi
X1
,
X23
Example:
Esc
1,Podium camNI
Nmi01,Podium cam
Name input 1 “Podium cam”.
Read
input name
Esc
X1
NI
X23
Write
output name
Esc
X1
,
X23
NO
Nmo
X1
,
X23
Example:
Esc
1,Main PJ1NO
Nmo01,Main PJ1
Name output 1 “Main PJ1”.
Read
output name
Esc
X1
NO
X23
I/O Grouping
Write input grouping
Esc X10
1
X10
2
…
X10
n
I
GrI
X10
1
X10
2
X10
3
…
X10
n
Each
X10
entry is the group
number assigned to an input
position, starting from input 1,
n is the maximum number of
inputs for this model.
Example for CrossPoint 450 Plus 3232:
Esc
I40…33
See below
01
Input:
GrI
Response #s = group:
Input 1 in group 4
02 03 04 05 06 07 08 09 10 11 12
4 0 1 3 3 0 0 0 0 4 4 4 4 1 1 2 2 1 2 2 3 3 3 3
13 14 15 16 17 18 19 20 21 22 23 24
Input 2 not grouped
2 1 2 2 3 3 3 3
25 26 27 28 29 30 31 32
Input 32 in group 3
Input 1 - Group 4, Input 2 - Group
0 (not grouped),…Input 31 -
Group 3, Input 32 - Group 3.
Write output grouping
Esc X10
1
X10
2
…
X10
n
O
Each
X10
entry is the group
GrO
X10
1
X10
2
…
X10
n
number assigned to an output
position, starting from output 1,
n is the maximum number of
outputs for this model.
Read input grouping
Esc
I
X10
1
X10
2
X10
3
…
X10
n
One
X10
entry for each input,
starting from input 1, n is the
maximum number of inputs for
this model.
Example for CrossPoint 450 Plus 2424:
Esc
I
See below
01
Input:
Response = group:
Input 1 in group 1
02 03 04 05 06 07 08 09 10 11 12
1 1 1 3 3 0 0 0 0 4 4 4 4 1 1 2 2 1 2 2 3 3 3 3
13 14 15 16 17 18 19 20 21 22 23 24
Input 9 not grouped
Input 24 in group 3