Programmer’s Guide, cont’d
CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide
4-16
Command/Response Table for IP SIS Commands
Symbol Definitions:
X30
= Matrix name
(Up to 240 characters)
The following characters are invalid in the name: {space} ~ , @ = , ‘ [ ] { } < > ’ “ ; : | \ and ?.
X31
= Default name
Factory default name (model name + last 3 pairs of MAC address).
X32
= Time and date (set)
MM/DD/YY•HH:MM:SS where:
MM = month: 01 (January) through 12 (December)
DD = day: 01 through 31
YY = year: 00 through 99
HH = hour: 00 through 24
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X33
= Time and date (read)
In the format: Day,•DD•Mmm•YYYY•HH:MM:SS where:
Day = weekday: Mon through Sun
DD = day: 01 through 31
Mmm = month: Jan through Dec
YYYY = year: 2000 through 2099
HH = hour: 00 through 24
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X34
= GMT offset
–12.0 t14.0. Hours and minutes removed from GMT
X35
= Daylight Savings Time
0 = Daylight Savings Time off/ignore
1 = Daylight Savings Time on (northern hemisphere)
2 = Daylight Savings Time on (Europe)
3 = Daylight Savings Time on (Brazil)
X36
= IP address
###.###.###.###
X37
= Hardware (MAC) address
##-##-##-##-##-##
X38
= Number of open connections 0 - 255
X39
= Password
12 digits, alphanumeric
The following characters are invalid in passwords: {space} + ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X40
= Domain name
Standard domain name conventions apply (for example, xxx.com)
The following characters are invalid in a domain name: {space} + ~ , = ‘ [ ] { } < > ’ “ ; : | \ and
?. The @ character is only acceptable as the lead-in to the domain name (such as @extron.com).
X41
= E-mail account
65 – 72. 65 = e-mail recipient #1, 66 = 2, 67 = 3, ..., 72 = recipient #8
X42
= E-mail address
Typical e-mail address format (for example: nnnnn@xxx.com)
X43
= Notify when?
0 = No response, 1 = fail/missing, 2 = fixed/restored, 3 = both 1 & 2
X44
= Notification selections
Matrix size 2412 and larger:
01 – 32 = input 1 through input 32
98 = power supplies
99 = fans
Matrix size 1616 and smaller: 01 – 16 = input 1 through input 16
17 = power supply
X45
= Notify status (for read)
34- or 17-digit number. For each digit: 0 = do not notify, 1 = notify
X46
= DHCP
(0 = off, 1 = on)
X47
= Port #
00 – 99 (00 = all ports)
X48
= Baud rate
9600, 19200, 38400, 115200
X49
= Parity
O
dd, even, none, mark, space (only first letter required)