Operation, cont’d
CrossPoint 450 Plus and MAV Plus Switchers • Operation
3-50
Rear Panel Controls
The rear panel has a Reset button that initiates four levels of matrix switcher resets.
Press and hold the button while the switcher is running or while you apply power
to the switcher for different reset levels.
Performing soft system resets
The CrossPoint 450 Plus and MAV Plus switchers have three soft resets available
that restore various tiers of switcher settings to their default settings.
•
Events (mode 3) reset —
This function toggles the monitoring of events on or
off (if events monitoring was on, this function turns it off; if it was on, it is
turned off).
•
IP settings (mode 4) reset —
The IP settings reset performs the following
functions:
!
Enables Arp program capability
!
Resets the IP address to the factory default (192.168.254.254)
!
Resets the subnet mask to the factory default ()
!
Resets the gateway address to its factory default ()
!
Resets port mapping to the factory default ()
!
Turn DHCP off
!
Turn events off
IP settings reset does not replace any user-installed firmware.
•
Absolute (mode 5) reset —
Absolute reset restores the switcher to the default
factory conditions. This function is identical to the
Esc
ZQQQ
SIS
command, see chapter 4, Programmer’s Guide).
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201
Fax 07131 911203