Time (local) field
The Time (local) field displays the current time in the local time zone. If necessary,
click on the Sync Time to PC button to set the switcher to your computer’s internal
time or else adjust the time manually as follows:
1
.
Click in the time field. A set time field appears with
the date in the format HH:MM:SS
(00:00:00 to 23:59:59). The graphic cursor becomes a text cursor in the set time
field.
2
.
Edit the field as desired to set the proper time. Remember to use 24-hour
time. Leading zeroes are optional.
3
.
Press the Tab key on the keyboard or click in another field to exit the set time
field.
4
.
Click the Take button to make the time change take affect.
Sync Time to PC button
Clicking the mouse on the Sync Time to PC button causes the computer you are
operating to send its internal time to the switcher in a set time command.
GMT (offset) field
The GMT field displays the amount of time, in hours and minutes, that the local
time varies from the GMT international time reference. If necessary, adjust the
offset as follows:
1
.
Click in the GMT field. A set offset field appears with the offset in
the format ±HH:MM (–12:00 to +14:00). The graphic cursor
becomes a text cursor in the set offset field.
2
.
Edit the field as desired to set the proper offset. Leading zeroes are optional.
Some time zones are on the half-hour (30 minutes).
3
.
Press the Tab key on the keyboard or click in another field to exit the Set
Offset field.
4
.
Click the Take button to make the offset change take affect.
Use Daylight Savings checkbox
Click in the Use Daylight Savings checkbox. When Daylight Savings Time is
turned on, the switcher automatically updates its internal clock between Standard
Time and Daylight Savings Time in the spring and fall on the date that the time
change occurs in the United States of America. When Daylight Savings Time is
turned off, the switcher does not adjust its time reference.
Administrator Password field
The Administrator Password field displays the password required to log on to the
CrossPoint 450 Plus or MAV Plus switcher via the Ethernet port with all of the administrator’s
rights and privileges. Passwords are case sensitive and are limited to 12 upper-case
and lower-case alphanumeric characters.
While you are logged on as a user, this field is masked with asterisks (************)
as a security measure.
Editing the Administrator Password field while connected via the Ethernet
port can immediately disconnect the user from the switcher. Extron
recommends editing this field using the RS-232/RS-422 link and protecting
the Ethernet access to this screen by assigning an administrator’s password to
qualified and knowledgeable personnel only.