Operation, cont’d
CrossPoint 450 Plus and MAV Plus Switchers • Operation
3-22
The I/O groups can be set up on the front panel or by using RS-232/RS-422 and
Ethernet ports and either the SIS or the Windows control program (see chapter 4,
Programmer’s Guide, and chapter 5, Matrix Software. Create I/O groups on the front
panel as follows:
1
.
Press the Esc button to clear any input buttons, output buttons, or control
buttons that may be lit.
2
.
To enter I/O Group mode, press and hold the Input 1 and Output 1 buttons
until the input and output buttons light to display the ungrouped inputs and
outputs.
3
.
Press and release one of the Control buttons to select a group:
•
Press the Enter button to select group 1.
•
Press the Preset button to select group 2.
•
Press the View button to select group 3.
•
Press the Esc button to select group 4.
4
.
Select the desired input(s) and output(s) to assign to the group by pressing the
input and output buttons.
5
.
Press and release the RGBHV/Video and Audio button to exit the I/O Group
mode, or allow the mode to time out after approximately 30 seconds.
•
Ties between groups (an input in group 1 tied to an output in group 2)
can
be created under RS-232/RS-422 or Ethernet control.
•
Presets can be created under RS-232/RS-422 or Ethernet control that tie
inputs and outputs across group boundaries. These presets are selectable
from the front panel.
•
An input or output can be assigned to only one group. If you assign an
input or output to a group and that input or output is already assigned to
a different group, the older grouping is discarded in favor of the new
grouping.
•
Audio can be broken away from the video for a given input or output
(assigned to different groups) by isolating only video or only audio using
the front panel RGBHV (CrossPoint 450 Plus)/Video (MAV Plus) and/or
Audio buttons after you select I/O Group mode (between steps 2 and 3).
Audio breakaway across different groups can be confusing when
operating the front panel; is not displayed by the Matrix Switchers
Control Program, HTML pages, or SIS commands; and is not
recommended.
•
For I/O groups to have any function, at least two groups must be created.