Chapter 10: System Messages
166
EVS5200_DOC_SOP_DS850
1009710 - Main Motor:
Error
X
X
During ballot scanning, when the Main
Transport Path Motor encounters an
error, ballot scanning stops and this
message appears on an error screen.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since this motor is a
“COTS” (Commercial Off The Shelf) product, the
ES&S Technician may have to contact a Datawin
Technician to diagnose the problem.
1009711 - Hopper
Drive: Error
X
X
During scanning, when the mechanical
drive for raising/lowering the ballot
stack support plate (for either the Input
Tray or the Bottom Output Bin)
encounters a problem, ballot scanning
stops and this error appears on a 'Scan
Ballots' error screen.
Select either 'Scan More' or 'Done' from the
error screen and follow the on-screen
instructions for clearing the error (which includes
clearing the Ballot Transport Path).
1009712 - PRECINCT
LABELS: NOT
SELECTED
X
This message appears on the initial
'Scan Ballots' screen, just prior to
scanning, when the election Processing
Mode is “By Style” and “NONE”
appears in the Precinct Label field.
Note:
An actual name (e.g. Precinct,
Borough, etc.) will appear in the place
of “Precinct label.
Press the screen's 'Precinct Label' button and
follow the on-screen instructions to select a
precinct.
System Messages
NOTE: A System Halt is a condition which requires the DS850 to be shutdown. It is not a condition which prevents the scanning of ballots.
Message Text
Message
Displayed
Message
Printed
Message
Logged
Results in a
System Halt
Cause
Resolution