Chapter 10: System Messages
162
EVS5200_DOC_SOP_DS850
1009555 - Error setting
ballot size
X
X
X
This message appears when an election
is loaded and the BAPis Image
Processor Board fails to set the ballot
size.
Write down the error message and notify an
appropriate election official. Repeat the
Clear-Initialize and Load Election steps. If the
same error reappears, shutdown and then turn
off the Scanner. Wait 30 seconds and then turn
the Scanner back on. If the problem persists, an
ES&S Customer Service Representative will need
to be contacted.
1009565 - Camera
Interface - No space for
image
X
X
X
This message appears when a ballot is
scanned and there is no room within the
buffer of the BAPis Image Processor
Board to store the image.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since the BAPis Board
is a “COTS” (Commercial Off The Shelf) product,
the ES&S Technician may have to contact a BAP
Technician to diagnose the problem.
1009566 - Camera
Interface - Error sending
image
X
X
X
This message appears when a ballot is
scanned and the Camera Interface
Board fails to send the image to the
BAPis Image Processor Board.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since both Camera
Interface and the BAPis Boards are “COTS”
(Commercial Off The Shelf) products, the ES&S
Technician may have to contact a BAP Technician
to diagnose the problem.
System Messages
NOTE: A System Halt is a condition which requires the DS850 to be shutdown. It is not a condition which prevents the scanning of ballots.
Message Text
Message
Displayed
Message
Printed
Message
Logged
Results in a
System Halt
Cause
Resolution