Chapter 10: System Messages
161
EVS5200_DOC_SOP_DS850
1009552 - Unable to
send file to Camera
Interface board
X
X
X
This message appears if the BAPis
Image Processor Board is unable to
send a file to a Camera Interface Board.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, contact an ES&S Service
Technician. Since both the Camera Interface and
BAPis Boards are “COTS” (Commercial Off The
Shelf) products, the ES&S Technician may have
to contact a BAP Technician to diagnose the
problem.
1009553 - Invalid Ballot
Key for Camera
Interface config INI file
X
X
X
This message appears at start-up when
the system attempts to initialize a
Camera Interface Board using an invalid
ballot key for the Board's config INI file.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since the Camera
Interface Board is a “COTS” (Commercial Off
The Shelf) product, the ES&S Technician may
have to contact a BAP Technician to diagnose
the problem.
1009554 - Camera
Interface thread not
started
X
X
X
This message appears at start-up when
the Master Control Program attempts
to start a task-execution-thread for the
Camera Interface process, but fails.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Customer Service
Representative will need to be contacted.
System Messages
NOTE: A System Halt is a condition which requires the DS850 to be shutdown. It is not a condition which prevents the scanning of ballots.
Message Text
Message
Displayed
Message
Printed
Message
Logged
Results in a
System Halt
Cause
Resolution