Chapter 10: System Messages
143
EVS5200_DOC_SOP_DS850
1009502 - Camera
Interface - No
connection
X
X
X
This message appears when the Master
Control Program cannot communicate
with the BAPis Image Processor Board
through the MCP/BAP Interface.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since the processor is
a “COTS” (Commercial Off The Shelf) product,
the ES&S Technician may have to contact a BAP
Technician to diagnose the problem.
1009503 - Camera
Interface - Not
implemented
X
X
X
This message appears when the Master
Control Program cannot communicate
with the BAPis Image Processor Board
because the MCP/BAP Interface is not
operating.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since the processor is
a “COTS” (Commercial Off The Shelf) product,
the ES&S Technician may have to contact a BAP
Technician to diagnose the problem.
1009504 - Camera
Interface - No image
data
X
X
X
This message appears when a ballot is
scanned but no image data is collected
through the MCP/BAP Interface.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since the BAPis Board
is a “COTS” (Commercial Off The Shelf) product,
the ES&S Technician may have to contact a BAP
Technician to diagnose the problem.
System Messages
NOTE: A System Halt is a condition which requires the DS850 to be shutdown. It is not a condition which prevents the scanning of ballots.
Message Text
Message
Displayed
Message
Printed
Message
Logged
Results in a
System Halt
Cause
Resolution