Chapter 10: System Messages
153
EVS5200_DOC_SOP_DS850
1009528 - Camera
Interface - Reset mode
not supported
X
X
X
This message appears if the system
cannot reset the BAPis Image Processor
Board to its initialized state.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since the BAPis Board
is a “COTS” (Commercial Off The Shelf) product,
the ES&S Technician may have to contact a BAP
Technician to diagnose the problem.
1009529 - Camera
Interface - Missing end
of image interrupt
X
X
X
This message appears if a ballot is
scanned and the BAPis Image Processor
Board cannot detect the interrupt signal
that indicates the end of the image has
been reached.
Write down the error message and notify an
appropriate election official. The system should
allow normal operations to resume. If this error
repeatedly occurs, shutdown and then turn off
the Scanner. Wait 30 seconds and then turn the
Scanner back on. If the problem persists, an
ES&S Service Technician will need to be
contacted. Since the BAPis Board is a “COTS”
(Commercial Off The Shelf) product, the ES&S
Technician may have to contact a BAP Technician
to diagnose the problem.
1009530 - Camera
Interface - Camera does
not support TLK RGB
pattern
X
X
X
This message appears if a ballot is
scanned and one or both of the
scan-cameras transmits the ballot image
to the BAPis Image Processor Board in
the form of a TLK RGB pattern, which
the board cannot process.
Write down the error message and notify an
appropriate election official. One or both of the
scan-cameras will need to be adjusted to
transmit in a different image format, so an ES&S
Service Technician will need to be contacted.
Since the BAPis Board is a “COTS” (Commercial
Off The Shelf) product, the ES&S Technician may
have to contact a BAP Technician to make the
adjustment(s).
System Messages
NOTE: A System Halt is a condition which requires the DS850 to be shutdown. It is not a condition which prevents the scanning of ballots.
Message Text
Message
Displayed
Message
Printed
Message
Logged
Results in a
System Halt
Cause
Resolution