Chapter 10: System Messages
154
EVS5200_DOC_SOP_DS850
1009531 - Camera
Interface - Cannot
communicate with
Virtex FPGA
X
X
X
This message appears if the BAPis
Image Processor Board failed to
communicate with a Virtex FPGA
(field-programmable gate array) device.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, the Virtex FPGA may need
to be replaced. Contact an ES&S Service
Technician. Since the BAPis Board is a “COTS”
(Commercial Off The Shelf) product, the ES&S
Technician may have to contact a BAP Technician
to fix the problem.
1009532 - Camera
Interface - Cannot
communicate with
Spartan FPGA
X
X
X
This message appears if the BAPis
Image Processor Board failed to
communicate with a Spartan FPGA
(field-programmable gate array) device.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, the Spartan FPGA may
need to be replaced. Contact an ES&S Service
Technician. Since the BAPis Board is a “COTS”
(Commercial Off The Shelf) product, the ES&S
Technician may have to contact a BAP Technician
to fix the problem.
System Messages
NOTE: A System Halt is a condition which requires the DS850 to be shutdown. It is not a condition which prevents the scanning of ballots.
Message Text
Message
Displayed
Message
Printed
Message
Logged
Results in a
System Halt
Cause
Resolution