Chapter 10: System Messages
152
EVS5200_DOC_SOP_DS850
1009526 - Camera
Interface - Image queue
corruption detected
X
X
X
This message appears if the BAPis
Image Processor Board detects
corruption of the Image Queue.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since the BAPis Board
is a “COTS” (Commercial Off The Shelf) product,
the ES&S Technician may have to contact a BAP
Technician to diagnose the problem.
1009527 - Camera
Interface - Image format
not supported
X
X
X
This message appears if the BAPis
Image Processor Board does not
support the format of the scanned
ballot image.
Write down the error message and notify an
appropriate election official. Attempt to rescan
the ballot in a different orientation (e.g. back of
ballot facing up). If that does not work, set that
ballot aside, with an appropriate note attached,
for an election official to examine later. Then
resume normal operations. If this error
repeatedly occurs, shutdown and then turn off
the Scanner. Wait 30 seconds and then turn the
Scanner back on. If the problem persists, an
ES&S Customer Service Representative will need
to be contacted.
System Messages
NOTE: A System Halt is a condition which requires the DS850 to be shutdown. It is not a condition which prevents the scanning of ballots.
Message Text
Message
Displayed
Message
Printed
Message
Logged
Results in a
System Halt
Cause
Resolution