Alarm Lists
E-38
EN/LZT 790 0023/1 R16A
E.5
Alarms List – Satellite Modulator
The following table lists the alarm and failure identifiers generated within the Media
Processing Module (MPM).
Table E.6 Alarm List – Satellite Modulator
Alarm
Description
Port Number
Alarm ID
Source
Severity
Over Temperature Warning
Failure to take action may cause
permanent damage to the unit.
Please check the fans are working
correctly, and that the ambient
temperature is not excessive
0
060F0001
Satellite
Modulator
minor
Over Temperature
Failure to take action may cause
permanent damage to the unit.
Please switch off and refer to
Customer Support
0
060F0002
Satellite
Modulator
critical
Option Card Build Version
Mismatch
The software on this option card is
not an officially released version
0
060F0008
Satellite
Modulator
minor
FPGA PLL Unlocked
FPGA PLL unlocked
0
060F000A
Satellite
Modulator
critical
Reference Clock Unlocked
10 MHz reference clock PLL
unlocked when Clock Reference set
to external
0
060F000B
Satellite
Modulator
minor
Clock PLL Unlocked
Clock generator PLL unlocked. This
alarm automatically turns off the IF
and L-band outputs
0
060F000C
Satellite
Modulator
critical
PSU Failed
12V power supply failed
0
060F001B
Satellite
Modulator
critical
Host SCR Sync Failed
Host SCR Sync Failed
0
060F0026
Satellite
Modulator
critical
Un-calibrated
Failed to load calibration data. Using
default data set. The RF output is
still present, but performance may
be degraded below published
specifications. For data recovery
please contact Customer Support
0
060F0027
Satellite
Modulator
major
Stream Input Data Rate Low
Stream input data rate low
0
060F000D
Satellite
Modulator
critical
Stream Input Data Rate High
Stream input data rate high
0
060F000E
Satellite
Modulator
critical
Primary Stream MPEG Sync Fail
Primary Stream MPEG sync fail
0
060F000F
Satellite
Modulator
critical
Secondary Stream MPEG Sync
Fail
Secondary Stream MPEG sync fail
0
060F0010
Satellite
Modulator
critical
Primary Stream BBFRAME Sync
Fail
Primary Stream BBFRAME sync fail
0
060F0011
Satellite
Modulator
critical
Secondary Stream BBFRAME
Sync Fail
Secondary Stream BBFRAME sync
fail
0
060F0012
Satellite
Modulator
critical
Input Buffer Overflow
Input buffer overflow
0
060F0013
Satellite
Modulator
critical
Summary of Contents for AVP 1000 1RU
Page 10: ...Preliminary Pages x EN LZT 790 0023 1 R16A BLANK...
Page 42: ...Installing the Equipment 2 18 EN LZT 790 0023 1 R16A BLANK...
Page 176: ...Front Panel Control 4 60 EN LZT 790 0023 1 R16A BLANK...
Page 319: ...Web GUI Control EN LZT 790 0023 1 R16A 5 143 Figure 5 43Support Page Device Management Tab...
Page 320: ...Web GUI Control 5 144 EN LZT 790 0023 1 R16A BLANK...
Page 324: ...Advanced Video Processing and Networking 6 4 EN LZT 790 0023 1 R16A BLANK...
Page 374: ...Options Licensing and Upgrades 7 28 EN LZT 790 0023 1 R16A BLANK...
Page 396: ...Preventive Maintenance and Fault finding 8 22 EN LZT 790 0023 1 R16A BLANK...
Page 444: ...Technical Specification B 28 EN LZT 790 0023 1 R16A BLANK...
Page 446: ...Audio Coding C 2 EN LZT 790 0023 1 R16A BLANK...
Page 452: ...Differences For Contribution Encoder and Voyager II D 2 EN LZT 790 0023 1 R16A BLANK...
Page 456: ...Differences For Contribution Encoder and Voyager II D 6 EN LZT 790 0023 1 R16A BLANK...
Page 458: ...Alarm Lists E 2 EN LZT 790 0023 1 R16A BLANK...
Page 500: ...Alarm Lists E 44 EN LZT 790 0023 1 R16A BLANK...
Page 502: ...Logo Creator F 2 EN LZT 790 0023 1 R16A BLANK...
Page 508: ...Logo Creator F 8 EN LZT 790 0023 1 R16A BLANK...